SPECIFICATIONS

Name

Description

Input

#3742-2-2 — 11V-14V DC Input

 

#

3742-2-4 — 21V-28V DC Input 

#3742-2-8 — 42V-56V DC Input

Output

115V AC

Output waveform

Modified Sine Waveform

Continuous power

3,000 watts

Surge power

6,000 watts

Efficiency

Approximately 90 %

No load current draw

  Switched ON

  Switched OFF

<1.0A DC

<0.2A DC

Battery low alarm

#3742-22 — 

10.5V ± 0.5V DC

 

#

3742-2-4 — 

21.0V ± 1.0V DC

 

#3742-2-8 — 

42.0V ± 2.0V DC

Battery low shutdown

#3742-22 — 

9.5V ± 0.5V DC

 

#

3742-2-4 — 

20.0V ± 1.0V DC

 

#3742-2-8 — 

40.0V ± 2.0V DC

AC output sockets

3 US standard grounded

Power switch

DC input ON/OFF control

Dimensions

13.5 x 6.5 x 6.0 in (34.3 x 16.5 x 15.2 cm)

Net Weight

8.8 lbs (4.0 kg)

Note:

All specifications are typical at nominal line, half load, and 77ºF (25ºC) unless otherwise noted.  

Specifications are subject to change without notice.

DISPOSAL OF INVERTER

Electronic products are known to contain materials that are toxic if improperly disposed. Contact 

local authorities for disposal and recycling information.

Содержание Proline 3000 3742-2

Страница 1: ...Item No 3742 2 12V DC Input 3742 4 24V DC Input 3742 8 48V DC Input Proline 3000 AC to DC Inverter User s Manual Please visit our website for the latest information on this product RoHS compliant...

Страница 2: ...Output AC Terminals 6 Remote ON OFF Switch Connection 6 Power Inverter Output Waveform 6 Inverter Output Characteristics 7 Rear Panel 7 High Speed Cooling Fan 7 Negative DC Input and Positive DC Input...

Страница 3: ...onnecting an Inverter 12 General information 12 Ground Terminal Wire Requirements 12 Cable Preparation 12 Inverter to Battery Connection Procedure 13 Charging the Battery Bank 14 Regular Loss of Comme...

Страница 4: ...ding fumes from flooded lead acid batteries Keep well ventilated this device generates heat Do not continuously operate your inverter at more than its rated output wattage Incorrect battery polarity w...

Страница 5: ...ipment All Modified Sine Wave MSW inverters may not properly operate some appliances with either speed control features or dimmer controls Some appliance GFCI power cords will not operate properly whi...

Страница 6: ...rter These are used to help diagnose problems if they occur Volts Display The volts display is the measurement of the voltage at the DC terminals of the inverter not actual battery voltage During high...

Страница 7: ...ection to distributed wiring that has multiple AC outlets Any wiring that is directly connected must be 10 gauge or larger Facing the front panel the terminals are Top Middle Bottom Live Black Neutral...

Страница 8: ...gh Speed Cooling Fan Positive DC Input Terminal High Speed Cooling Fan Fans operate automatically when the internal temperature of the inverter requires cooling Always allow free air flow Do not block...

Страница 9: ...otorized appliances will cause Do not exceed the surge rating of this inverter 3 000 watts this can cause immediate overload shut down At 5 000 watts continuous output this inverter requires a DC powe...

Страница 10: ...ged at a 1 amp rate is will take 20 hours to discharge that battery The terms charged and discharged relate to actual battery voltage This means that the output voltage of a nominal 12 volt battery st...

Страница 11: ...ries are flooded type they freely vent hydrogen and oxygen while under charging and heavy discharge They must be vented to outside air to prevent accumulation of explosive gases If the batteries are t...

Страница 12: ...protection Safety Ground 12V 220Ah 12V 220Ah 12V 220Ah INVERTER 12V DC Input Safety Ground 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah INVERTER 24V DC Input Safety Ground 48V DC Input...

Страница 13: ...to the positive terminal of the battery bank Use a length of string and follow the route the cables will follow Measure the length of string and then determine the correct gauge cable required for the...

Страница 14: ...rminals on the rear of the inverter 4 Tighten the retaining nuts 5 Connect all fuses end positive cable ring terminals to the positive battery bank terminal 6 Carefully tighten the retaining nuts DO N...

Страница 15: ...charger manual s s WARNING THERE IS DANGER OF EXPLOSION DO NOT CONNECT OR DISCONNECT CHARGER CABLES DIRECTLY AFTER BATTERY DISCHARGE OR RECHARGE MAKE SURE THAT THE BATTERY BANK AREA IS WELL VENTED BE...

Страница 16: ...ed value Recharge or replace battery Equipment being operated draws too much power Cable gauge may be inadequate use heavier cables Inverter is too hot thermal shut down mode Allow inverter to cool Ch...

Страница 17: ...0 2A DC Battery low alarm 3742 22 10 5V 0 5V DC 3742 2 4 21 0V 1 0V DC 3742 2 8 42 0V 2 0V DC Battery low shutdown 3742 22 9 5V 0 5V DC 3742 2 4 20 0V 1 0V DC 3742 2 8 40 0V 2 0V DC AC output sockets...

Страница 18: ...ery negative to inverter negative Use this Total Cable Length to determine the correct cable gauge in table in Appendix A Fuse Battery Bank INVERTER Positive Cable Positive Cable Negative Cable Total...

Страница 19: ...s This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be...

Страница 20: ...CA 94544 U S A Tel 1 510 471 9221 U S Canada Toll Free 1 800 231 5806 customerservice wagan com www wagan com 2015 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used b...

Отзывы: