manualshive.com logo in svg
background image

User’s Manual—Read before using this equipment

7

TROUBLESHOOTING

Jumpstart Warning Lights

The iOnBoost is ready to jumpstart when the cables are connected and a steady green light 

illuminates on the cable safety block. The following chart displays the combinations of warning 

lights that occur when the iOnBoost fails to display the ready light:

Warning lights Type of warning

Solution

Flashing red 

and green 

lights

No vehicle battery detected
Cables are not making a 

good connection
Vehicle battery voltage too 

high for jumpstarting

Check cable connection.
Check terminals for corrosion.

Check with a mechanic for other starting 

related  issues.

Solid red and 

green lights

90-second timer has 

expired; the smart cable 

has shut down

Disconnect cables from both the battery and 

the iOnBoost and follow connection procedure 

again.

Solid red light

(no green)

iOnBoost charge is too low 

for jumpstarting

The iOnBoost needs to be recharged.

Solid red light 

with beep 

 (no green)

Short-circuit

Disconnect immediately and follow proper 

connection procedure again.

Solid red light 

with pulsing 

beep 

(no green)

Reverse polarity

Disconnect immediately and follow proper 

connection procedure again.

Solid red light 

with slow beep 

(no green)

Reverse charge

Disconnect the iOnBoost from the vehicle 

battery immediately.

Solid red light 

with fast beep 

 (no green)

Over-heating

Disconnect and allow unit to cool for 10 

minutes.

Содержание 7505

Страница 1: ...User s Manual We are constantly improving our products so specifications are subject to change without notice Item No 7505 LITHIUM JUMP STARTER ...

Страница 2: ...ENTS Important Information 1 General Warnings 1 Features 1 Specifications 2 Care Maintenance 2 Product Diagram 3 Charging the iOnBoost 4 Jumpstarter 4 Troubleshooting 7 DC Power Port 8 Using the USB Ports 8 LED Flashlight 8 Proper Disposal 8 ...

Страница 3: ...onsible for their safety For proper and safe operation of any accessory outlet do not place anything in it except the plug of the accessory to be used Use only the charging adapters and jumpstarting clamps provided in this package Unauthorized parts may cause serious damage or injury Wear complete eye and clothing protection when jumpstarting a vehicle Do not touch eyes while working with battery ...

Страница 4: ...olymer Battery capacity watt hours 31 0 Wh Peak amps 800 A Cranking amps 400 A Jumper cables 10 AWG 13 inch USB power port 1x 5v 2 0A 1x rapid charge port Flashlight LED with 3 lighting modes Operating temperatures 32 F 140 F Storage temperatures 32 F 140 F Input 5V 2 0A Recharging time 7 hours CARE MAINTENANCE This unit may be stored in any position Make sure the clamps are secure inside the boos...

Страница 5: ...10 11 9 8 Actual contents may differ slightly from that pictured 1 Power button 2 USB C charging jack 3 Battery status indicator 4 5V 2A USB port 5 Rapid charging USB port 6 Flashlight 7 Jumper terminal 8 Storage case 9 Jumper cables 10 USB C charging cable 11 DC charging adapter ...

Страница 6: ... the gases away from the battery for a few minutes Do not use plastic or metal sheet they can produce sparks and ignite the gas Jumpstart cables connected to iOnBoost are ALWAYS live Never allow the clamps to touch together or contact the same piece of metal Do not attempt to jumpstart your vehicle when iOnBoost is below 80 charge observe battery status indicator lights on the unit 80 4 solid ligh...

Страница 7: ...pped 6 Securely connect the negative black clamp to a non moving metal part of the engine or frame as far away from the vehicle battery as possible 7 When the clamps are properly connected to the battery the green light on the cable safety block will illuminate a three second delay is normal When the light illuminates steady green it is safe to proceed in these instructions If the light fails to i...

Страница 8: ...itive red clamp to positive battery terminal 1 Connect cables to iOnBoost 3 Connect negative black clamp to solid metal ground on engine or frame away from battery 1 2 3 ORDER OF DISCONNECTION 2 Disconnect positive red clamp from positive battery terminal 1 Disconnect negative black clamp from frame 3 Disconnect cables from iOnBoost ...

Страница 9: ...th a mechanic for other starting related issues Solid red and green lights 90 second timer has expired the smart cable has shut down Disconnect cables from both the battery and the iOnBoost and follow connection procedure again Solid red light no green iOnBoost charge is too low for jumpstarting The iOnBoost needs to be recharged Solid red light with beep no green Short circuit Disconnect immediat...

Страница 10: ... will shut off to prevent damage to the iOnBoost Recharge the iOnBoost as soon as convenient 1 Hold down the Power button for 3 seconds to turn on the light 2 Short press to cycle through the lighting modes 1 strobe 2 S O S 3 off or long press to turn off from any mode 3 Recharge battery as soon as convenient PROPER DISPOSAL This product has no consumer serviceable parts Do not attempt to remove o...

Отзывы: