User’s Manual—Please read before using this equipment.
5
Over Temp LED
Internal high speed cooling fans automatically turn on when the inverter requires additional
cooling. The inverter may overheat when it is being used in a location that does not allow
adequate ventilation. If the continuous power requirement of the appliance(s) being operated
exceeds 3,000 watts, the inverter will overheat. The Over Temp LED will turn RED and the
inverter will automatically shut down. If this occurs, turn OFF the inverter and determine the
cause of the overheat condition before turning the inverter ON.
Digital Display
The inverter is equipped with a digital LCD display to diagnose system operations if there
are problems. The display will continuously change every 20 seconds to show:
DC input voltage (nominal 12.5VDC)
AC output voltage (nominal 115VAC)
Watts delivered to the AC load.
DC voltage reading is the measurement of the voltage between the DC input terminals of
the inverter, not the actual battery voltage. During high wattage applications the display
may show a lower voltage level than the battery because of the voltage drop that occurs
between the input cables and the battery. This voltage drop should not be excessive as this
will seriously reduce run time. This inverter will operate with an input voltage ranging from
11 to 15 Volts of direct current (DC). If the inverter input voltage level falls below 10.5 Volts
DC, an audible alarm will sound. Should the voltage drop below 10 Volts DC, the inverter
will automatically shut down.
During charging from a generator, solar panel or AC powered charger, the battery voltage
will be higher than when it is resting. This inverter will shutdown if the input voltage is 15
Volts. It will shut down automatically if this occurs. However, in some rare cases voltages
greater than 15 may cause damage to the inverter. Damage caused by excessive voltage
input is not covered under warranty.
Two 115VAC Outlets.
Each outlet will supply 15 Amps 115VAC maximum for powering appliances. Greater than
1,650 watts continuous power from an outlet may cause damage to the inverter and cause
possible injury.
High Output AC Terminals
There are three insulated terminals on the front panel of the inverter. These terminals are for
connecting 115 volt AC devices that require more than 15 amps to operate. Other uses are
for connection to distributed wiring that has multiple AC outlets. Any wiring that is directly
connected must be 10 gage or larger. Facing the Front Panel terminals are:
Left
Middle
Right
Neutral
Hot
Ground
•
•
•
© 2008 Wagan Corporation.