Replacing the fuse
PerfectPower
24
Observe the following when using the device
If the battery voltage falls below 10.8 V (PP152/PP402/PP602) or 21.5 V
(PP154/PP404/PP604) during operation, a warning tone sounds. If the
battery voltage falls further, the inverter switches off and the red error LED
(fig.
1
2, page 2) lights up.
If the inverter overheats, it switches off – the red error LED (fig.
1
2, page 2)
lights up.
➤
If this happens, switch the inverter off with the switch.
When it cools down, you can use the inverter again.
When operating the inverter at a high load for lengthy periods, it is advisable
to start the engine in order to recharge the vehicle battery.
You can operate the inverter with the engine running or switched off.
However, do not start the engine while the inverter is switched on, since the
power supply to the cigarette lighter is disconnected during ignition.
8
Replacing the fuse
This is how to change the fuse of the inverter:
➤
Take the defective fuse (fig.
2
3, page 3) out of the holder on the back.
➤
Put in a new fuse of the same rating.
9
Cleaning and caring for the inverter
A
NOTICE!
Do not use sharp or hard objects or cleaning agents for cleaning as
these may damage the product.
➤
Occasionally clean the product with a damp cloth.
_PP150_PP400_PP600.book Seite 24 Montag, 7. Mai 2012 9:45 09
Содержание PerfectPower PP402
Страница 2: ...PerfectPower 2 POWER FAULT 4 5 1 2 3 4 5 1 2 3 PP152 PP154 PP402 PP404 PP602 PP604 1...
Страница 4: ...PerfectPower 4 A B 3 25 cm 25 cm RE VE RS E PO LA RI TY CH AS SIS P 4 1 2 5...
Страница 132: ...RU PerfectPower 132 1 133 2 133 3 136 4 136 5 137 6 138 7 140 8 141 9 141 10 142 11 142 12 143 13 143...
Страница 133: ...RU PerfectPower 133 1 D A I 1 5 3 5 1 3 2...
Страница 134: ...RU PerfectPower 134 2 1 2 2...
Страница 135: ...RU PerfectPower 135 230 12 24 2 3 60 C 230 1 1 2 230...
Страница 138: ...RU PerfectPower 138 6 A 2 6 1 25 4 4 40 C A...
Страница 139: ...RU PerfectPower 139 5 4 6 2 PP152 PP154 15 A 12 PP152 24 PP154 1 4 2 1 5 2 6 3 PP402 PP404 PP602 PP604 1 4 2 1 5 2...
Страница 140: ...RU PerfectPower 140 7 2 1 3 ON OFF REMOTE 1 1 2 2 1 3 ON 1 3 2 2 1 3 OFF 1 3 2 2 1 3 REMOTE 2 4 3 3 4 1 3 2...
Страница 141: ...RU PerfectPower 141 10 8 PP152 PP402 PP602 21 5 PP154 PP404 PP604 1 2 2 1 2 2 8 2 3 3 9 A...
Страница 142: ...RU PerfectPower 142 10 11 PP152 PP154 12 24 10 8 PP152 PP402 PP602 21 5 PP154 PP404 PP604...
Страница 169: ......
Страница 170: ......
Страница 171: ......