CombiCool
Troubleshooting
29
9
Troubleshooting
In the event of malfunction, please check the following:
Fault
Possible cause
Suggested remedy
The cooler does
not work.
The cooler is not
properly connected to
the electricity supply.
Check if the voltage supply is in full working order.
Check if all electrical contacts are in full working
order.
Check if the voltage supply corresponds to the
value on the type plate.
Check if the thermostat control is switched on.
Check if several energy sources are connected at
the same time.
The cooler is not
properly connected to
the gas.
Check if the gas supply is in full working order.
Check if the valve on the gas bottle is open.
Check if there is still gas in the bottle.
Check if several energy sources are connected at
the same time.
Hold the rotary switch longer when igniting.
The cooler has not
been set up properly.
Check if the device is horizontal.
Check if the ventilation of the device is sufficient.
The cooler has not
been filled properly.
Check if warm food has been put into the device.
Check if the cooling space has been overfilled or
packed too densely.
The refrigerant circuit
is defective.
This can only be repaired by an authorised
repair centre.
The cooler does
not start up after
a long period of
inactivity.
–
Disconnect the device from the energy supply and
turn the cooler upside down and wait around five
minutes.
Turn the cooler the right way up again and switch
it on again.