ColdMachine
Technical data
55
Test/certificates:
Versions, technical modifications and delivery options reserved.
This device is CFC-free.
The coolant circuit contains R134a.
Vaporiser
VD-16
VD-21
Max. cooling area
content at 60 mm PU
insulation:
130 litres
250 litres
Max. cooling area
content at 100 mm PU
insulation:
200 litres
300 litres
Power consumption:
60 W
60 W
Voltage
12 V DC or 24 V DC
Dimensions (WxHxD) in
mm:
330x260x130
1370x305x10
Weight:
2.5 kg
4.0 kg
Vaporiser
VD-16 for series 80
VD-16 for series 90
Max. cooling area
content at 35 mm PU
insulation:
120 litres
200 litres
Max. cooling area
content at 50 mm PU
insulation:
200 litres
250 litres
Power consumption:
65 W
80 W
Voltage
12 V DC or 24 V DC
Dimensions (WxHxD) in
mm:
380x300x62
Weight:
5.0 kg
_coldmachine.book Seite 55 Mittwoch, 30. April 2008 3:26 15
“More information https://www.caravansplus.com.au"