Technical description
BordBar CDF-11
22
4.2
Operating and display elements
Control panel (fig.
2
, page 2)
Item Description
Explanation
1
On/Off button
Switches the cooler on or off when the button is
pressed for between one and two seconds
2
POWER
Status indication
LED lights up green
Compressor is on; preset
temperature isn’t reached
yet
LED lights up orange
Preset temperature is
reached
LED flashes orange
Insufficient voltage
3
ERROR
LED flashes red
Device is switched on but
not ready for operation
4
SET
Selects the input mode
– Set Temperature
– Set temperature unit (Celsius or Fahrenheit)
– Set battery monitor
5
Display
Shows the temperature inside the cooling compart-
ment
The first three digits of the four-digit display show the
temperature, the fourth digit shows the temperature
unit (°C or °F).
In case of an error the display shows the error mes-
sage “Err1” or “Err2”.
6
+
Press once to increase the value
7
–
Press once to decrease the value
_CDF-11.book Seite 22 Dienstag, 18. August 2009 7:22 19
www.busse-yachtshop.de | [email protected]