41
VAS 581 001A
Operation
8.7
Free selection
I
The following four processes can be run in isolation from the
“Free
selection”
menu:
Rec/Recycling phase: analyzing the refrigerant (see chapter “Analyz-
ing refrigerant” on page 25), extraction, recycling of the refrigerant,
pressure rise test, draining the waste oil.
Vacuum phase: evacuating the system, leak test/vacuum check.
Filling phase: Before working on the vehicle air conditioner, a leak
inspection must be carried out. The air conditioner is filled with a
sample refrigerant for this. The pressure in the air conditioner must
remain constant over a period of 5 minutes. The air conditioning unit
can only be completely filled if this test has been successfully
completed. The sample filling is then drained and the air conditioner
evacuated. The final filling quantity is completely filled up to ensure
high filling accuracy.
Filling with fresh oil, filling of UV additive, filling of refrigerant.
Select connections: Air conditioning has high and low pressure
connection, only high pressure or only low pressure connection
After each process has been performed, a service report is printed.
1. Start by fitting the connections of the AirConServiceCenter to the
vehicle air conditioning system, and opening them.
2. In the basic menu, use the cursor keys
or
to select
“Free selection”
:
3. Press
ENTER
to confirm.
4. Enter the vehicle data and press
ENTER
to confirm.
NOTE
The
“Free selection”
menu is used to conduct air conditioning servic-
ing step-by-step. You can perform the same processes as in the short
selection menu, but also omit individual procedures. In addition, it is
possible to enter the values for each individual process using the
keypad. You can also enter the vehicle data for the service report in this
menu.
Short selection
Free selection
Other selections
ENTER-OK
VAS-581-001A--O-US.book Seite 41 Montag, 17. Februar 2020 8:25 20