EN
Service tasks
ASC 5300 G
108
9
Service tasks
9.1
Leak test
Check the AirConServiceCenter once a year for leaks in accordance with
the applicable legal requirements. Use an electronic leak detector for this
purpose.
9.2
Calibrating the oil scales
I
1. In the basic menu, use the cursor keys
or
to select
“Other selections”
:
2. Press
ENTER
to confirm.
3. Use the cursor keys
or
to select
“Reset scales”
:
✓
You are then prompted to remove the containers from the scale:
NOTE
In order for the oil quantities and the UV additive to be measured
correctly, the zero point of the scales must be checked regularly and
reset if necessary.
Resetting is necessary:
If the quantity in a container deviates by more than 10 ml from the
target value
If the AirConServiceCenter has been shaken, for example during
transport on bumpy roads
Every four to six weeks
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.
Remove the 3 Oil/UV
glasses from scales.
ENTER-OK STOP-EXIT
ASC5300G_OPM_DE-EN-ES-FR-RU.book Seite 108 Freitag, 26. Juni 2020 5:42 17
Содержание AirCon Service Center ASC 5300 G
Страница 66: ...DE Technische Daten ASC 5300 G 66 ASC5300G_OPM_DE EN ES FR RU book Seite 66 Freitag 26 Juni 2020 5 42 17...
Страница 132: ...EN Technical data ASC 5300 G 132 ASC5300G_OPM_DE EN ES FR RU book Seite 132 Freitag 26 Juni 2020 5 42 17...
Страница 198: ...ES Datos t cnicos ASC 5300 G 198 ASC5300G_OPM_DE EN ES FR RU book Seite 198 Freitag 26 Juni 2020 5 42 17...
Страница 267: ...FR 267 ASC 5300 G Caract ristiques techniques ASC5300G_OPM_DE EN ES FR RU book Seite 267 Freitag 26 Juni 2020 5 42 17...
Страница 321: ...RU 321 ASC 5300 G 9 9 1 14 K 2 K K ASC5300G_OPM_DE EN ES FR RU book Seite 321 Freitag 26 Juni 2020 5 42 17...
Страница 334: ...RU ASC 5300 G 334 13 2 ASC5300G_OPM_DE EN ES FR RU book Seite 334 Freitag 26 Juni 2020 5 42 17...
Страница 335: ...RU 335 ASC 5300 G ASC5300G_OPM_DE EN ES FR RU book Seite 335 Freitag 26 Juni 2020 5 42 17...