Maintenance
VP 1340A/VP 1550A
wpm_tx001088gb.fm
20
4.2
Spark Plug
See Graphic: wc_gr000028
Clean or replace the spark plug as needed to ensure proper operation.
Refer to your engine operator’s manual.
The muffler becomes very hot during operation and remains hot for a
while after stopping the engine. Do not touch the muffler while it is hot.
Note:
Refer to section “Technical Data” for the recommended spark
plug type and the electrode gap setting
.
4.2.1
Remove the spark plug and inspect it.
4.2.2
Replace the spark plug if the insulator is cracked or chipped.
4.2.3
Clean the spark plug electrodes with a wire brush.
4.2.4
Set the electrode gap
(a)
.
4.2.5
Tighten the spark plug securely.
NOTICE
:
A loose spark plug can become very hot and may cause
engine damage
.