Maintenance
PS (3-Phase) Series
wc_tx000132gb.fm
26
Note:
The gasket and the O-ring for the oil plug must be replaced with
a new part at each oil inspection and change.
Replacement Parts
The table lists the parts that need to be replaced periodically. Replace
these using the recommended frequency as a guideline.
Model
Specified Lubricant Capacity
PS2 1503
PS2 2203
PS3 1503
PS3 2203
740 ml (25.0 fl.oz.)
PS2 3703
PS4 3703
PS3 3703
960 ml (32.5 fl.oz.)
PS4 5503
PS3 5503
1100 ml (37.2 fl.oz.)
PS4 7503HH
PS4 11003HH
PS4 7503HF
PS4 11003HF
760 ml (25.7 fl.oz.)
Part
Replacement Frequency
Mechanical seal
Lubrication oil discolored
Lubricant (SAE 10W/20W)
Every 6,000 hours or 12 months, whichever comes first.
Gasket and O-ring
Each time pump is disassembled or inspected.
Oil seal (1.5 to 5.5 kW)
[2 to 2.7 HP]
Each time pump is disassembled or inspected or if the
sealing lip is worn
Ring-sealing (7.5/11 kW)
[10/15 HP]
When it becomes worn.
Sleeve (except 3.7/5.5 kW)
[5 / 7.5 HP]
When it becomes worn.