HI 110 / 200 / 300
Operation
ghi_tx001447gb.fm
37
4.16
Burner Faults
The burner fault lamp / reset button
(a)
is illuminated while the machine is
operating. The lamp is green during normal operation.
Burner fault
A burner fault occurs if the burner does not start after two failed attempts to start or
restart upon shutdown. The lamp will turn red.
f
To clear a burner fault, press and hold the burner fault lamp / reset button for
2–3 seconds until the lamp goes out.
f
Re-start the machine.
f
If the burner fault re-occurs, see
Basic Troubleshooting.
WARNING
If three consecutive attempts to reset the machine are unsuccessful, then troubleshoot the
heating system for the root cause(s) of the lockout.
f
Make necessary repairs or adjustments to ensure a safe start condition.
f
Ensure that the heat exchanger is free of oil and oil vapors before starting or resetting
the burner.