4.4
Servicing the Air Cleaner
Service the air cleaner frequently to prevent carburetor malfunction.
NOTICE
: NEVER
run the engine without the air cleaner. Severe
engine damage will occur.
NEVER
use gasoline or other types of low flash-point solvents for
cleaning the air cleaner. A fire or explosion could result.
To service:
4.4.1
Remove the air cleaner cover
(a)
. Inspect the element
(b)
for holes or
tears. Replace the element if it is damaged.
4.4.2
Wash the foam element
(b)
in a solution of mild detergent and warm
water. Rinse it thoroughly in clean water. Allow the element to dry
thoroughly. Soak the element in clean engine oil and squeeze out
excess oil.
WARNING
wc_gr002815