G 3.3A
Maintenance
wc_tx000161gb.fm
31
5.11 Troubleshooting
Problem / Symptom
Reason / Remedy
If engine doesn't start, check
that:
•
Engine switch is on "Start".
•
Fuel valves under fuel tank and on engine are open.
•
Fuel tank has fuel.
•
Choke lever is in correct position. Choke should be
closed when starting a cold engine.
•
All loads are disconnected from generator.
•
Spark plug is in good condition.
•
Spark plug cap is tight.
•
Engine oil level is adequate.
If engine starts but there is no
power at receptacles, check
that:
•
Circuit breaker is closed.
•
Connector from generator to control panel is tight.
If engine starts but runs errati-
cally, check that:
•
Hose routing from the fuel tank to the engine is cor-
rect. For proper operation, the hose must run
through the bushing in the lifting bracket. Refer to
the Parts Book for illustration.
Wire Colors
B
Black
R
Red
Y
Yellow
Or
Orange
G
Green
T
Tan
Br
Brown
Pr
Purple
L
Blue
V
Violet
Cl
Clear
Sh
Shield
P
Pink
W
White
Gr
Gray
LL