wc_tx001197gb_FM10.fm
189
Mobile Generators
Troubleshooting
20 Troubleshooting
Problem
Cause
Remedy
Engine doesn’t start
Battery discharged
Battery connections
corroded
Blown fuse
Defective starter
Charge battery.
Clean battery connections.
Replace fuse.
Replace starter.
Engine tries to start but
stops
No fuel
Clogged fuel filter
Fuel circuit failure
Fill tank with fuel.
Bleed fuel lines.
Replace fuel filter.
Check fuel lines.
No generator output
Main circuit breaker open
Lug door open
Close main circuit breaker.
Close lug door.
Low oil pressure
Low oil level
Clogged oil filter
Fill engine sump with oil.
Replace oil filter.
High coolant temperature
Overload
Low coolant level
Low oil level
Clogged oil filter
Reduce load.
Fill with coolant.
Fill sump with oil.
Replace oil filter.
Engine emits black smoke
Clogged air filter
Overload
High oil level
Clean/replace air filter
cartridges.
Reduce load.
Remove excess oil.
Содержание G 230
Страница 1: ...5000186930 09 0215 5 0 0 0 1 8 6 9 3 0 Operator s Manual Mobile Generator G 230 G 240 EN ...
Страница 6: ...Foreword 6 wc_tx003565gb_FM10 fm Notes ...
Страница 25: ...wc_tx003568gb_FM10 fm 25 Mobile Generator Label Locations wc_gr009229 UU G H J R GG V V WW FF R A KK H ...
Страница 178: ...wc_tx003849gb_FM10 fm 178 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770051 ...
Страница 179: ...wc_tx003849gb_FM10 fm 179 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770052 ...
Страница 180: ...wc_tx003849gb_FM10 fm 180 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770048 ...
Страница 184: ...wc_tx003663gb_FM10 fm 184 Engine Maintenance T4i Cummins QSB6 7 770016 ...
Страница 211: ...wc_tx003111gb_FM10 fm 211 User s Information for Transport Canada Fuel Tank ...
Страница 212: ...wc_tx003111gb_FM10 fm 212 User s Information for Transport Canada Fuel Tank ...
Страница 252: ......
Страница 253: ......