Technical data
43
13.4
Extension cable
Only use permitted extension cables, see chapter
Safety
.
Refer to the following table for the required cross-section area of the exten-
sion cable:
Note:
Refer to the nameplate or the chapter
Technical data
(via the item
number) for the type designation and voltage rating of your machine.
*** According to ISO 11201
****Determined according to DIN EN ISO 5349.
WARNING
Electrical voltage.
Injuries from electrocution.
f
Check power cable and extension cable for signs of damage.
f
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data
).
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
100 1~
< 17
1.5
< 29
2.5
< 46
4
< 68
6