wc_tx001951gb.fm
75
E 3000
Operation
Lockout
The lockout state is described below.
Recycle
The recycle mode is described below.
State
Action or Function
Lockout
The burner will enter the lockout state for the following reasons:
Trial for ignition time has expired without flame being estab-
lished.
Cad cell detects flame at the end of the valve-on delay state.
Recycle time budget expires.
Relay check failure.
Note:
The burner control cannot reset by interrupting the
voltage.
During the lockout state:
The burner will not fire.
The red reset button / lockout light on the burner control will
flash during a soft lockout condition.
The reset button / lockout light will remain on continuously
during a hard lockout condition.
The burner fault light on the control panel will illuminate.
To clear the soft lockout fault so a restart can be attempted,
press and release the reset button.
Note:
After the third attempt
to manually clear the lockout fault, the burner control will enter
the hard lockout mode. To clear the hard lockout, press and
hold the reset button for 15 seconds.
wc_gr007665
Yellow
pump prime
Green
flame / recycle
Red
Reset button / lockout
State
Action or Function
Recycle
The burner will enter the recycle mode if the flame is lost while
the burner is firing.
During the recycle mode:
The burner control shuts down the burner.
The burner control enters a 60-second delay, then repeats
the ignition sequence.
The green flame / recycle light on the control panel flashes.
The burner control attempts to recycle each time the flame is
lost, up to three times. If flame is not established after the
third time, the burner control enters the hard lockout state.
To clear the hard lockout fault so a restart can be attempted,
press and hold the reset button for 15 seconds.
Содержание E 3000 LB
Страница 6: ...Foreword wc_tx002028gb fm 6 ...
Страница 22: ...Labels E 3000 wc_si000643gb fm 22 2 Labels 2 1 Label Locations 603 wc_gr008850 998 608 626 602 601 999 618 ...
Страница 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes ...
Страница 44: ...wc_tx001951gb fm 44 Operation E 3000 4 5 Control Panel wc_gr008606 1 2 n d e f g h i j k l m a b c o p ...
Страница 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes ...
Страница 95: ...ghi_tx001162gb fm 95 E 3000 Accessories wc_gr008559 2 1 1 2 x z a b c LR RR RS LS HX 50 HX 50 HX 50 ...
Страница 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50 ...
Страница 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50 ...
Страница 101: ...ghi_tx001162gb fm 101 E 3000 Accessories wc_gr008580 SPP HX 100 HX 100 HX 100 d e a b c LR RR y LS RS APP 2 1 ...
Страница 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS ...
Страница 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS ...
Страница 107: ...ghi_tx001162gb fm 107 E 3000 Accessories wc_gr008584 APP c e d DPP a b LR LS RR RS 2 1 HX 200 HX 200 ...
Страница 182: ...MSDS Dowfrost HD 50 ...
Страница 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller ...
Страница 199: ...Tire Safety Information ...
Страница 200: ...wc_tx001952gb fm 200 Schematics E 3000 12 Schematics 12 1 Composite Schematic Machine with Oil Burner ...
Страница 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner ...
Страница 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit ...
Страница 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit ...
Страница 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic ...
Страница 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator ...
Страница 213: ......