Faults
T01008GB.fm
5
7
6.5
The charge control lamp will not extinguish
and/or the buzzer will not stop buzzing
6.6
Engine does not start
6.7
Compaction display unit
If all LEDs stay on following initialization, the sensor test was not
successful.
Cause
Remedy
Dynamo defective.
Contact Wacker Neuson service dept.
Control unit defective.
Replace control unit (on rear of the
dynamo).
Cause
Remedy
Ignition lock defective.
Change defective parts.
Starter defective.
Start knop defective.
Battery flat.
Charge battery.
Lack of lubricating oil.
Fill up with oil and actuate valve lever
at oil filter housing once.
Cause
Remedy
The engine was running when the
sensor was switched on
Contact Wacker Neuson service dept.
Sensor defective