MAINTENANCE
Engine oil
Check oil level:
Check oil level on oil dipstick (21). If the
oil level is too low, top up with oil Fuchs Titan Unic 10W40 MC though the filler nozzle (22).
Changing the oil:
1. Let engine warm up.
2. Loosen screw (25) at the engine/clamp.
3. Guide hose outwards through the large opening in the protective frame.
4. Fully unscrew drainage screw (24) and fill used oil into an appropriate container.
5. Screw in drain plug (24) and install hose back onto engine.
6. Fill engine through filler neck (22) with 2.5 liters of Fuchs Titan Unic 10W40 MC oil.
Battery
Check acid level:
1. Open right maintenance cover.
2. Check acid level and top up with distilled water if necessary.
3. Close maintenance cover again.
☛
ATTENTION! Be sure to check if the positive pole cover is in the correct position before closing the
maintenance cover.
Note:
Only replace a defective battery with an original Wacker battery. Conventional batteries
are not designed to withstand the high vibration load.
4. When changing the battery pay close attention to the following:
Removal:
first disconnect the negative, then the positive pole.
Assembly:
first connect the positive, then the negative pole
.
See chapter on “Emergency start“ for external start.