![Wacker Neuson BPS1030 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/wacker-neuson/bps1030/bps1030_operators-manual_3214984039.webp)
Shutdown
Temporary decommissioning 11.1
39
[us] | 07/2021 | 5100060589 | BPS | Operator’s Manual
11
Shutdown
11.1
Temporary decommissioning
Information
Further information and detailed descriptions,
page 31
.
Storage requirements
• Store dust-free and dry.
• Do not store outdoors.
• Protect from direct sunlight.
• Observe the storage temperature,
see Technical Data on page 42
.
• Store in a locked place that is not accessible to children.
If the machine is stationary for more than 1 month, perform the following
measures:
Entire machine
• Clean thoroughly.
• Check for leaks, rectify any defects if necessary.
Fuel tank
Plastic tank
:
• Drain fuel completely.
Metal tank:
• Refill with fuel.
Engine
• Check engine oil level, fill engine oil if necessary.
• Check and clean air filter.
• Clean fuel filter.
Components susceptible to corro-
sion
Oil and grease.
11.2
Final shutdown
If the machine is no longer in use and is shut down for good, all operating
fluids must be drained.
Have the machine professionally dismantled and disposed of by a state-
approved recycling company.
Professional disposal of this machine avoids negative effects on human
health and the environment, helps with the targeted treatment of pollu-
tants and makes it possible to recycle valuable raw materials.