10 Maintenance
29
100_0302_mt_0001.fm
10 Maintenance
10.1
Maintaining the Emission control system
Normal maintenance, replacement, or repair of emission control devices and systems may be performed
by any repair establishment or individual; however, warranty repairs must be performed by a dealer/
service center authorized by Wacker Neuson
The use of service parts that are not equivalent in performance and durability to authorized parts may
impair the effectiveness of the emission control system and may have a bearing on the outcome of a
warranty claim.
10.2
Maintenance personnel qualifications
Qualifications for maintenance work
The maintenance work described in this operator's manual may be performed by any responsible user
unless otherwise stated.
Some maintenance work may only be performed by specially trained personnel or by the service staff of
your Wacker Neuson contact — these are specifically noted.
10.3
Maintenance schedule
WARNING
Improper handling can result in injury or serious material damage.
Read and follow all safety instructions of this operator's manual, see chapter
Safety
.
WARNING
Danger of poisoning by exhaust fumes.
Exhaust fumes contain toxic carbon monoxide that can lead to unconsciousness or death.
Carry out maintenance work only when the engine is off.
Task
Daily
before
operation
Every
20 hrs.
Every
40 hrs.
Monthly
Annually
Visual inspection of all parts for damage.
Clean the machine.
Ventilation slots.
Air cleaner.
Check the fuel:
Fuel tank fill level.
Fuel tank for leaks.
Lines for leaks.
Check the tool ends and cutting edges – if
required, sharpen, reforge or replace.
BH 55
Lubricate the machine.
BH 55rw, BH 65
Lubricate the machine.
Clean spark plug – change, if necessary.
Check tool holder for wear – have it changed,
if necessary.*
Have the fuel filter replaced.*
*
Have these tasks carried out by the service department of your Wacker Neuson contact person.