External vibrators

SV00079GB.fm

9

Protecting the power cable

Do not use the power cable to pull or lift the machine.
Do not unplug the mains cable by pulling on the cable.
Protect the mains cable from heat, oil and sharp edges.
If the power cable is damaged or the plug is loose, have it replaced immediately 
by your WACKER representative.

2.7

Safety during the operation of external vibrators

Attaching the safety strap

If using the external vibrator in conjunction with a clamp, always attach the clamp 
to the formwork using the safety belt supplied.
Attach the safety belt above the external vibrator securely to the formwork. The 
safety belt should be taut without slack to ensure the clamp and the external 
vibrator are caught by the safety belt in the event of a fall and stopped from falling 
too far.

Motor protection against overload

To protect the motor against overload, WACKER recommends the use of a 
motor-protective circuit-breaker. 

Using stable formwork

Only use stable molds and formwork for attaching the external vibrator. Tighten 
the fastening screws.
Molds and formworks that are not firm enough or loose connections may 
overload the motor or result in being damaged themselves.
Check whether your formwork is suitable for receiving external vibrators:

„

Attachment possibility.

„

Sufficient stability for the used external vibrator type (dependent on the 
performance).

Your WACKER representative will be happy to assist you.

Using the correct clamp

Attach the external vibrator using the clamp which is suitable for the external 
vibrator and the formwork.

2.8

Maintenance

Maintenance work

Service and maintenance work must only be carried out to the extent described 
in these operating instructions. All other procedures must be performed by your 
WACKER representative.
For further information, please see the chapter 

Maintenance

.

All manuals and user guides at all-guides.com

all-guides.com

Содержание 0008933

Страница 1: ...Operator s Manual External vibrator AR 36 0109966en 007 12 2009 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...All manuals and user guides at all guides com...

Страница 3: ...nd distribution are reserved Copyright 2008 by Wacker Construction Equipment AG No part of this publication may be reproduced in any form or by any means electronic or mechanical including photocopyin...

Страница 4: ...4 5 Connection 18 4 6 Adjustment of centrifugal force 18 5 Maintenance 19 5 1 Maintenance schedule 19 6 Eccentric 20 6 1 Centrifugal forces table AR 36 3 230 Vario 21 6 2 Centrifugal forces table AR 3...

Страница 5: ...improper Any damage resulting from improper use will void the warranty and the liability on behalf of the manufacturer The operator assumes full responsibility Structural modifications Never attempt t...

Страница 6: ...to persons or for damage to materials in the following cases Structural modifications Improper use Improper handling Use of spare parts and accessories not produced by WACKER Operator s manual Always...

Страница 7: ...ualifications Only trained personnel are permitted to start and operate the machine The following rules also apply You are physically and mentally fit You have received instruction on how to independe...

Страница 8: ...s Personal protective gear Wear personal protective gear to avoid injuries or health hazards Non skid hard toed shoes Work gloves made of durable material Overalls made of durable material Hardhat Ear...

Страница 9: ...manual Vertical stability Always make sure that you maintain a safe distance when working with the machine This applies particularly when working on scaffoldings ladders etc Switching off the machine...

Страница 10: ...andard fault current protective switch AC sensitive type A AC DC sensitive fault current protective switch type B The machine may only be connected to an electric power supply with all machine parts i...

Страница 11: ...e motor against overload WACKER recommends the use of a motor protective circuit breaker Using stable formwork Only use stable molds and formwork for attaching the external vibrator Tighten the fasten...

Страница 12: ...the machine from the electric power supply Before carrying out service or maintenance work pull the mains plug out of the plug receptacle in order to disconnect the machine from the electric power sup...

Страница 13: ...500 Frequency Hz 50 0 87 50 Rated current A 1 75 1 3 1 68 0 75 0 6 Vibrations min 1 3000 0 5220 3000 Centrifugal force Standard kN 2 61 0 3 28 2 61 2 70 Centrifugal force max kN 2 93 0 3 28 2 93 3 47...

Страница 14: ...Frequency Hz 60 Rated current A 3 5 1 3 1 68 0 75 Vibrations min 1 3600 Centrifugal force Standard kN 2 51 2 56 Centrifugal force max kN 2 97 3 44 Class rating I Type of protection IP 65 Sound pressur...

Страница 15: ...ency Hz 60 Rated current A 0 68 0 65 0 63 Vibrations min 1 3600 Centrifugal force Standard kN 2 56 Centrifugal force max kN 3 44 Class rating I Type of protection IP 65 Sound pressure level LPA at ope...

Страница 16: ...ge V 42 3 Frequency Hz 200 Rated current A 9 Vibrations min 1 6000 Centrifugal force Standard kN 2 17 2 3 Centrifugal force max kN 3 47 Class rating III Type of protection IP 65 Sound pressure level L...

Страница 17: ...d current A 9 3 7 1 7 Vibrations min 1 6000 Centrifugal force Standard kN 2 85 1 74 2 85 Centrifugal force max kN 3 47 Class rating III I Type of protection IP 65 Sound pressure level LPA at operator...

Страница 18: ...A 6 0 Vibrations min 1 12000 Centrifugal force Standard kN 1 74 Centrifugal force max kN 3 47 Class rating III Type of protection IP 65 Sound pressure level LPA at operator s station dB A below 70 Th...

Страница 19: ...ng blocks and machines In building construction and civil engineering to be used as form vibrators in all pre cast concrete factories to fit planks plates etc for AR 36 with 3000 and 3600 vibrations p...

Страница 20: ...he rating plate Connect equipment designed for normal frequencies to an appropriate supply network Connect equipment designed for high frequencies to a WACKER frequency and voltage converter with an a...

Страница 21: ...rts Maintenance jobs Maintenance intervals Supply cable 11 Check for perfect condition replace defective cable daily External vibrator 1 Tighten all accessible screw connections after first 20 hours A...

Страница 22: ...direction position 1 or at an angle of 120 one to another position 2 Hence the centrifugal forces can be adjusted in several different ways 1 By removing individual flywheel discs 2 By turning individ...

Страница 23: ...0 98 4 74 10 1 08 5 27 9 1 0 93 8 2 0 78 7 3 0 66 6 4 0 57 5 5 0 54 8 1 0 82 7 2 0 68 6 3 0 56 5 4 0 5 7 1 0 71 6 2 0 57 5 3 0 47 4 4 0 43 6 1 0 6 5 2 0 47 4 3 0 39 5 1 0 5 4 2 0 38 3 3 0 33 4 1 0 39...

Страница 24: ...3 5 2 1 43 4 3 1 18 5 1 1 51 4 2 1 14 3 3 0 99 4 1 1 18 3 2 0 87 3 1 0 87 2 2 0 66 2 1 0 57 1 1 0 33 Number of eccentric weights per Number of eccentric weights per Centrifuga l Moment of inertia side...

Страница 25: ...27 11 1 19 5 79 12 1 3 6 32 13 1 41 6 85 14 1 52 7 37 15 1 63 7 9 16 1 74 8 43 17 1 84 8 95 18 1 95 9 48 19 2 06 10 01 20 2 17 10 53 21 2 28 11 06 22 2 39 11 58 23 2 5 12 11 24 2 6 12 64 25 2 71 13 1...

Страница 26: ...eights per Centrifuga l Moment of inertia side Pos 1 side Pos 2 kN 10 4 kgm2 20 1 2 12 19 2 1 96 18 3 1 81 17 4 1 67 16 5 1 54 15 6 1 42 14 7 1 32 13 8 1 23 12 9 1 17 11 10 1 14 19 1 2 01 18 2 1 85 17...

Страница 27: ...6 0 65 10 1 1 04 9 2 0 89 Number of eccentric weights per Number of eccentric weights per Centrifuga l Moment of inertia side Pos 1 side Pos 2 kN 10 4 kgm2 8 3 0 76 7 4 0 66 6 5 0 6 9 1 0 93 8 2 0 78...

Страница 28: ...5 79 12 1 3 6 32 13 1 41 6 85 14 1 52 7 37 15 1 63 7 9 16 1 74 8 43 17 1 84 8 95 18 1 95 9 48 19 2 06 10 01 20 2 17 10 53 21 2 28 11 06 22 2 39 11 58 23 2 5 12 11 24 2 6 12 64 25 2 71 13 16 26 2 82 1...

Страница 29: ...eccentric weights per Centrifuga l Moment of inertia side Pos 1 side Pos 2 kN 10 4 kgm2 20 8 1 89 19 9 1 79 18 10 1 69 17 11 1 62 16 12 1 56 15 13 1 53 14 14 1 52 26 1 2 77 25 2 2 61 24 3 2 46 23 4 2...

Страница 30: ...f eccentric weights per Centrifuga l Moment of inertia side Pos 1 side Pos 2 kN 10 4 kgm2 17 4 1 67 16 5 1 54 15 6 1 42 14 7 1 32 13 8 1 23 12 9 1 17 11 10 1 14 19 1 2 01 18 2 1 85 17 3 1 71 16 4 1 56...

Страница 31: ...8 3 0 76 7 4 0 66 6 5 0 6 Number of eccentric weights per Number of eccentric weights per Centrifuga l Moment of inertia side Pos 1 side Pos 2 kN 10 4 kgm2 9 1 0 93 8 2 0 78 7 3 0 66 6 4 0 57 5 5 0 54...

Страница 32: ...4 74 10 1 56 5 27 11 1 72 5 79 12 1 87 6 32 13 2 03 6 85 14 2 19 7 37 15 2 34 7 9 16 2 5 8 43 17 2 66 8 95 18 2 81 9 48 19 2 97 10 01 18 1 2 74 17 2 2 51 16 3 2 3 15 4 2 1 14 5 1 92 13 6 1 76 12 7 1...

Страница 33: ...8 1 1 18 7 2 0 98 6 3 0 81 5 4 0 72 7 1 1 02 6 2 0 83 5 3 0 68 4 4 0 62 6 1 0 87 5 2 0 68 4 3 0 56 5 1 0 72 Number of eccentric weights per Number of eccentric weights per Centrifuga l Moment of inert...

Страница 34: ...1 41 4 74 10 1 56 5 27 11 1 72 5 79 12 1 87 6 32 13 2 03 6 85 14 2 19 7 37 15 2 34 7 9 16 2 5 8 43 17 2 66 8 95 18 2 81 9 48 19 2 97 10 01 20 3 12 10 53 21 3 28 11 06 22 3 44 11 58 21 1 3 21 20 2 2 9...

Страница 35: ...r of eccentric weights per Centrifuga l Moment of inertia side Pos 1 side Pos 2 kN 10 4 kgm2 12 1 1 8 11 2 1 59 10 3 1 39 9 4 1 22 8 5 1 09 7 6 1 02 11 1 1 65 10 2 1 43 9 3 1 24 8 4 1 08 7 5 0 98 6 6...

Страница 36: ...nt of centrifugal force in factory 3 47 kN 2 30 kN Thickness 1 5 Borehole diameter d 14 Number of eccentric weights per Number of eccentric weights per Centrifuga l Moment of inertia side Pos 1 side P...

Страница 37: ...ine max 4 4 External diameter D 84 Adjustment of centrifugal force in factory 1 74 kN Thickness 1 5 Borehole diameter d 14 Number of eccentric weights per Number of eccentric weights per Centrifuga l...

Страница 38: ...e that all the labels are kept legible Replace any missing or illegible labels The item numbers for the labels are in the parts book Item Label Description 1 Warning Warning of hot surface Read the op...

Страница 39: ...Decal SK00127GB fm All manuals and user guides at all guides com...

Страница 40: ...itable recycling operation for environmental friendly reuse or recycling During disposal observe the regional rules and regulations e g the European Directive for obsolete electical and electronic dev...

Страница 41: ...This is to certify that this product meets and complies with the relevant regulations and re quirements of the following guidelines and standards 2006 42 EC 2006 95 EC Authorized person for technical...

Страница 42: ...All manuals and user guides at all guides com...

Страница 43: ...All manuals and user guides at all guides com...

Страница 44: ...All manuals and user guides at all guides com...

Отзывы: