FF 424 FLANGE FACING SYSTEM
SECTION V
FF 424 SET UP AND OPERATING PROCEDURES
A.
FF 424 SET UP
1.
Measure the flange l.D.
Refer to mandrel leg extension chart ( See
page 13) To select the mandrel adaptor and
leg Set required to mount in flange l.D.
2.
Insert the solid leg set # 66-077-01 in the
mandrel head “POINT SIDE DOWN”
(Figure 1)
NOTE:
66-077-01 solid leg set is required
when installing the 66-090-00 adaptor
or the 66-092-00 adaptor onto the
mandrel head.
4. Select extension leg set required. Refer to
the l.D. range chart decal provided on the leg
extension box, or on page 13 in this manual.
3. Mount the selected adaptor over the
mandrel head and secure with the provided
3 SHCS (Figure 2)
(Figure 2)
(Figure 1)
(Figure 3)
5. Install the adjustment screw into the adjust-
able leg and tighten completely. (Figure 4)
ABOUT THE ADJUSTABLE LEG:
An adjustable leg has been provided to compen-
sated centering on slip over or butt welded
flanges when mandrel placement must be inside
the pipe I. D.
(Figure 4)
9.
29
Содержание SDB 412
Страница 2: ......
Страница 6: ...SDB 412 and FF 424 4 Part No 66 MAN 01 Rev A E H Wachs...
Страница 12: ...SDB 412 and FF 424 10 Part No 66 MAN 01 Rev A E H Wachs...
Страница 24: ...22...
Страница 40: ...SDB 412 and FF 424 38 Part No 66 MAN 01 Rev A E H Wachs SDB 412 Air Drive 66 000 01 NOTE...
Страница 41: ...Operating Envelopes E H Wachs Part No 66 MAN 01 Rev A 39 SDB 412 Hydraulic Drive 66 000 03 NOTE...
Страница 48: ...SDB 412 and FF 424 46 Part No 66 MAN 01 Rev A E H Wachs...
Страница 66: ...SDB 412 and FF 424 66 Part No 66 MAN 01 Rev A E H Wachs...
Страница 69: ......
Страница 70: ...600 Knightsbridge Parkway Lincolnshire IL 60069 847 537 8800 www ehwachs com...