Technical Manual
WDGA with CANopen-Interface
6 - WDGA object dictionary
© Wachendorff Automation GmbH & Co. KG
28
Rev.1.24
6.3 Manufacturer specific objects
The objects 2000h to 5FFFh are manufacturer specific and not defined by the CiA.
Object
No.
Name
Sub
Idx
Function
Data type
ro
rw
co
Map
Default
value
2100h
Baudrate
00h Setting the baudrate
Unsigned8
rw
no
09h
2101h
Node-ID
00h Setting the node-ID
Unsigned8
rw
no
7Fh
2103h
BUS-Off
Auto-Reset
00h Defines the time in
BUS OFF, before
automatically
resetting. 0h = no
automatic reset, 01h-
FFh = time in sec.
Unsigned8
rw
no
00h
2105h
Integration
value
00h Number of values for
filtering speed,
acceleration and jerk
Unsigned8
rw
no
02h
01h Integration-Position
value filter
Unsigned8
rw
01h
02h Integration-Speed
value filter
Unsigned32
rw
03E8h
2106h
Speed
scaling
00h Speed value scaling
Unsigned8
co
no
02h
01h Multiplier
Unsigned16
rw
0001h
02h Divisor
Unsigned16
rw
0001h
2107h
Frequency-
Limit
00h Limit for Speed value
Unsigned16
rw
no
FFFFh
2120h
Customer
EEPROM
area
00h Object to store any
customer data.
Unsigned8
co
no
08h
01h Customer data 1
Unsigned32
rw
FFFF FFFFh
02h Customer data 2
Unsigned32
rw
FFFF FFFFh
03h Customer data 3
Unsigned32
rw
FFFF FFFFh
04h Customer data 4
Unsigned32
rw
FFFF FFFFh
05h Customer data 5
Unsigned32
rw
FFFF FFFFh
06h Customer data 6
Unsigned32
rw
FFFF FFFFh
07h Customer data 7
Unsigned32
rw
FFFF FFFFh
08h Customer data 8
Unsigned32
rw
FFFF FFFFh
2500h
p. 38
Temperature
Object
00h Monitoring the
internal operating
temperature
Unsigned8
co
yes
05h
01h Current temperature
value
Signed16
ro
dyn
02h Upper Limit
Signed16
rw
100 (°C)
03h Lower Limit
Signed16
rw
-40 (°C)
04h Maximum value
occurred
Signed16
ro
dyn
05h Minimum value
occurred
Signed16
ro
dyn
Table 6.11: manufacturer specific objects 2100h –2500h
Содержание WDGA CANopen
Страница 1: ...R e v 1...