Wachendorff ETHSW50K Скачать руководство пользователя страница 12

Operating and Installation Instructions 

 

 

 

- 12 - 

Stand: 24.05.2019 

10. 

Copyright 

This  document  is  the  property  of  Wachendorff  Prozesstechnik  GmbH  &  Co.KG.  Copying  and 
duplication are prohibited without prior permission. The contents of this documentation refer to the 
device described therein.  
 

11.   Exclusion of liability 

All  technical  content  within  this  document  is  subject  to change  without  notice.  The  content  of  the 
document is the content of a recurring revision. 
In  the  event  of  loss  due  to  fire,  earthquake,  intervention  by  third  parties  or  other  accidents,  or 
intentional or accidental misuse or abuse, or use under abnormal conditions, repairs will be charged 
to the user. Wachendorff Prozesstechnik is not liable for any accidental loss resulting from the use 
or non-use of this product, such as loss of business profits. 
Wachendorff Prozesstechnik is not liable for the consequences of improper use.  
 

12. 

Other provisions and standards 

FCC Conditions 

This equipment has been tested and found to comply with Part 15, Class B of the FCC 
Rules. Operation is subject to the following two conditions: 
(1)  This  equipment  may  not  cause  harmful  interference,  which  can  cause  harmful 

interference to radio or television reception. 
(2) This device must accept any interference received, including interference caused by undesired 
operation. 
 

WEEE Information 

Disposal of old electrical and electronic equipment (valid in the European Union and other 
European countries with separate collection system). This symbol on the product or on the 
packaging  means  that  this  product  must  not  be  treated  as  household  waste.  Instead,  this 

product  should  be  taken  to  the  appropriate  disposal  point  for  recycling  electrical  and  electronic 
equipment.  If  the  product  is  disposed  of  correctly,  you  help  to  prevent  negative  environmental 
influences  and  damage  to  health  that  could  be  caused  by  improper  disposal.  The  recycling  of 
materials  will  preserve  our  natural  resources.  For  more  information  about  recycling  this  product, 
please contact your local Citizen Office, your household waste collection service or the store where 
you purchased this product.  
 

13.   Customer service and technical support 

For technical questions you can reach us under:  
 

 

 
Industriestraße 7 - 65366 Geisenheim, Germany 
Phone: +49 6722 9965-966

 

Fax: +49 6722 9965-78 
E-mail: [email protected] 
Homepage: www.wachendorff-prozesstechnik.de 
 

Содержание ETHSW50K

Страница 1: ...endorff de www wachendorff prozesstechnik de Copyright by Wachendorff Prozesstechnik GmbH Co KG Industriestra e 7 D 65366 Geisenheim Germany Tel 49 6722 9965 20 Fax 78 All information is subject to ch...

Страница 2: ...llation 6 5 1 Mechanical Installation 6 5 1 1 Mounting on the DIN rail 6 5 2 Electrical Installation 7 5 2 1 Connecting the power supply 7 5 2 2 Connection of the fail safe relay 8 5 2 3 Connecting th...

Страница 3: ...conditions on machines and systems Machines and systems must be designed in such a way that faulty states cannot lead to a situation that is dangerous for the operating personnel e g by independent l...

Страница 4: ...l Duplex and Back Pressure Half Duplex Interfaces RJ45 Ports copper 5x 10 100BaseT X RJ45 Speed Auto Negotiation 10 100 Mbps RJ45 Duplex Half or Full Duplex RJ45 Connection MDI MDIX Auto Crossover Fau...

Страница 5: ...CE EMS IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 Level 3 RoHS and WEEE RoHS lead free and WEEE compliant Housing Degree of protection IP30 Execution Robust polycarbonate housing...

Страница 6: ...or proper mounting on the DIN rail 1 Tilt the module backwards with the top and press it onto the DIN rail Align the module straight 2 Press the module down on the DIN rail until it is properly fixed...

Страница 7: ...ide a suitable 12 to 58 VDC power source and connect it by tightening the screws to the 6 pole terminal plug at the terminals provided for this purpose o P1 Primary power supply o P2 Secondary power s...

Страница 8: ...ssage contact Power Alarm at PIN 1 of the DIP switch ON A L M P1 P2 Clamp ALM ALM DIP PIN 1 Signal Connection to alarm system Connection to alarm system ON 5 2 3 Connecting the network devices The ETH...

Страница 9: ...thernet link established link up data transmission Off Ethernet link not established link down RJ 45 Ports Port 1 to 5 Speed On yellow Ethernet link with 100 Mbit s established Off Ethernet link with...

Страница 10: ...ation Instructions 10 Stand 24 05 2019 8 PIN assignment of the network connection RJ 45 to RJ 45 straight through cable PIN 1 2 3 4 5 6 7 8 Signal Tx Tx Rx Rx RJ 45 cross over cable PIN 1 2 3 4 5 6 7...

Страница 11: ...Operating and Installation Instructions 11 Stand 24 05 2019 9 Dimensions of the ETHSW50K series in mm 25 00 113 00 4 50 7 33 90 05 97 38...

Страница 12: ...onditions 1 This equipment may not cause harmful interference which can cause harmful interference to radio or television reception 2 This device must accept any interference received including interf...

Отзывы: