Alarms
WORD
R
An alarm is set when a
malfunction bit is set to true. The
alarm remains active until it is
cleared, and the device is able to
operate correctly again.
Bit 0: Position Error
Bit 1: Diagnostic Error
Bit 2...11: reserved
Bit
12...15:
manufacturer
specific
45
Supported Alarms
WORD
R
Contains the information about
the supported alarms of the
device.
Bit 0: Position Error
Bit 1: Diagnostic Error
Bit 2...11: reserved
Bit
12...15:
manufacturer
specific
46
Alarm Flag
BOOL
R
The flag indicates whether an
alarm error has occurred. It
corresponds to a logical OR of
all alarm bits of attribute 44
47
Warnings
WORD
R
The warnings indicate when
certain parameters of the device
are not adhered to or when limit
values are exceeded.
All warnings are deleted as soon
as the parameters are back in
the normal range.
Bit 0: Frequency exceeded
Bit 10: Position Limits exceeded
Bit 11...12: reserved
Bit
13...15:
manufacturer-
specific
48
Supported
Warnings
WORD
R
This
attribute
contains
information about the supported
warnings of the device.
Bit 0: Frequency Exceeded
Bit 10: Position Limits Exceeded
Bit 11...12: reserved
Bit
13...15:
manufacturer
specific
49
Warning Flag
BOOL
R
This flag signals when a warning
error
has
occurred.
It
corresponds to a logical OR of
all alarm bits of attribute 47.