![WAC Lighting InvisiLED CCT 100 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/wac-lighting/invisiled-cct-100/invisiled-cct-100_installation-instruction_3115533005.webp)
5
Flex Tape to Tape X Connector (T24-X-WT, T24-X-BK)
7.
Connect electrical power feed connector to any connector on the tape or accessories. There is no polarity.
Power feed and connectivity can be done with all directions.
Hard Wire:
•
Enclosed 24VDC CCT class 2 output remote power supply must be installed away from any heat sources
and it must be accessible for service.
•
Enclosed 24VDC CCT class 2 output remote power supply is UL listed.
•
The power supply box has a separate line voltage, and low voltage wiring compartments.
•
Trade size knock out are provided on both compartments. Connect building wires to the same color power
supply wires with wire nuts or UL certified electrical connector.
•
Building ground wire may be green or uninsulated, and attaches to green wire from power supply box.
•
Additional power feeds and wiring components are available.
Portable:
•
24VDC CCT class 2 output plug-in power supply plugs into standard 120-277VAC volts 3 prong grounded
outlet. •
•
CCT Power Supply must be installed away from the heat sources.
8.
Slide the switch position to a desirable color temperature (CCT) on the power supply