WAC Lighting InvisiLED CCT 100 Скачать руководство пользователя страница 5

 

 
Flex Tape to Tape X Connector (T24-X-WT, T24-X-BK) 
 

 

 
 

7. 

Connect electrical power feed connector to any connector on the tape or accessories. There is no polarity. 
Power feed and connectivity can be done with all directions. 

 

 

 

 

 

 

 

 

 

 

 

 

Hard Wire:  

 

Enclosed 24VDC CCT class 2 output remote power supply must be installed away from any heat sources 
and it must be accessible for service.  

 

Enclosed 24VDC CCT class 2 output remote power supply is UL listed.  

 

The power supply box has a separate line voltage, and low voltage wiring compartments.  

 

Trade size knock out are provided on both compartments. Connect building wires to the same color power 
supply wires with wire nuts or UL certified electrical connector.  

 

Building ground wire may be green or uninsulated, and attaches to green wire from power supply box. 

 

Additional power feeds and wiring components are available.  
 

 

Portable:  

 

24VDC CCT class 2 output plug-in power supply plugs into standard 120-277VAC volts 3 prong grounded 
outlet. •  

 

CCT Power Supply must be installed away from the heat sources. 

 

8. 

Slide the switch position to a desirable color temperature (CCT) on the power supply

 

 
 
 
 