background image

                      Nieaf-Smitt is a brand name of 

Wabtec

NETHERLANDS

NI 14R

True RMS Stroomtang

Handleiding

True RMS Current Clamp

Manual

Содержание Nieaf-Smitt NI 14R

Страница 1: ...Nieaf Smitt is a brand name of Wabtec NETHERLANDS NI 14R True RMS Stroomtang Handleiding True RMS Current Clamp Manual...

Страница 2: ...blic in any form or manner either electronically mechanically by photocopying recording or in any manner without prior written consent from Wabtec Netherlands B V This also applies to accompanying dra...

Страница 3: ...elijkstroom 10 4 3 Gelijk wisselspanning 11 4 4 Frequentie duty cycle 11 4 5 Weerstand 12 4 6 Diodes en continuiteit 12 4 7 Capaciteit 13 4 8 Temperatuur 14 4 9 Contactloos wisselspanning 14 5 Functie...

Страница 4: ...erstand Zet de functieschakelaar op OFF uit wanneer de meter niet in gebruik is Waarschuwingen Zet de functieschakelaar op de juiste stand voordat u gaat meten Zet de meter niet in de standen stroom o...

Страница 5: ...t geteste apparaat voordat u diodes weerstand of continu teit meet Het meten van spanning bij ingebouwde stopcontacten kan lastig en misleidend zijn omdat u niet weet of de elektrische contactpunten z...

Страница 6: ...anning 3 Trekker 4 Knop HOLD en schermverlichting 5 Draaischakelaar 6 Knop voor Hz en 7 Knop MODE modus instellen 8 Knop REL relativiteit instellen 9 Lcd scherm 10 COM aansluiting 11 V CAP TEMP Hz aan...

Страница 7: ...Meetwaarden tot 6000 0 t m 5999 in analoge weergave balk met 61 segmenten 4 AUTO Auto bereikmodus 5 REL Relatieve modus 6 Diodetestmodus 7 Alarmtoon continu teit 8 HOLD Modus gegevens vasthouden 9 oC...

Страница 8: ...2 digits 6 000 VDC 1 5 2 digits 60 00 VDC 600 0 VDC Wisselspanning 50 400 Hz 6 000 VAC 1 8 8 digits 60 00 VAC 600 0 VAC Weerstand 600 0 1 0 4 digits 6 000 K 1 5 2 digits 60 00 K 600 0 K 6 000 M 2 5 3...

Страница 9: ...Bedrijfstemperatuur 5 o C 40 o C 40 o F 104 o F Opslagtemperatuur 20 o C 60 o C 4 o F 1404 o F Vochtigheidsgraad in bedrijf Maximaal 80 bij maximaal 31 o C 87 o F lineair afnemend tot 50 bij 40 o C 1...

Страница 10: ...AAC of 600 AAC 2 Als het meetbereik niet bekend is begint u bij het hoogste bereik en selecteert u daarna een lager bereik indien nodig 3 Druk de trekker in om de klem te openen plaats deze geheel op...

Страница 11: ...herm 4 4 Frequentie duty cycle meten elektronisch 1 Zet de draaischakelaar op stand V 2 Selecteer ACV met behulp van de knop MODE Modus 3 Druk op de knop Hz om de betreffende status op het scherm weer...

Страница 12: ...cd scherm 4 6 Diodes en continu teit meten 1 Plaats de zwarte banaanstekker in de negatieve COM aansluiting en de rode banaanstekker in de positieve diodeaansluiting 2 Zet de draaischakelaar op stand...

Страница 13: ...u wilt meten 5 De gemeten capaciteit wordt weergegeven op het scherm 4 8 Temperatuur meten WAARSCHUWING Ontkoppel beide meetkabels van eventuele spanningsbronnen voordat u de temperatuur meet om elekt...

Страница 14: ...aarvan u zeker weet dat er spanning op staat 1 Raak met de meetsonde het meetpunt aan dat onder spanning staat of steek de meetsonde in de kant van het stopcontact die onder stroom staat 2 Bij de aanw...

Страница 15: ...ng 5 4 Knop HOLD gegevens vasthouden Druk op de knop HOLD om de meetwaarde op het lcd scherm te bevriezen De knop HOLD bevindt zich aan de linkerkant van de meter bovenste knop Als de HOLD modus actie...

Страница 16: ...ting verlicht het scherm en wordt ingeschakeld bij weinig omgevingslicht zodat de weergegeven meetwaarden kunnen worden afgelezen Druk 2 seconden op de knop om de schermverlichting in te schakelen en...

Страница 17: ...4 2 DC current 24 4 3 DC AC voltage 25 4 4 Frequency duty cycle 25 4 5 Resistance 26 4 6 Diode and continuity 26 4 7 Capacitance 27 4 8 Temperature 27 4 9 Non contact voltage 28 5 Functions 5 1 MODE...

Страница 18: ...e appropriate position before measuring When measuring volts do not switch to current resistance modes When changing ranges using the selector switch always disconnect the test leads from the circuit...

Страница 19: ...essed electrical contacts Other means should be used to ensure that the terminals are not live If the equipment is used in a manner not specified by the manufacturer the protection provided by the equ...

Страница 20: ...ndicator light 3 Clamp trigger 4 Data Hold and Backlight button 5 Rotary Function swith 6 Hz Hlod button 7 RANGE select button 8 Relative button 9 MIN MAX Hold button 10 MODE select button 11 LCD disp...

Страница 21: ...2 Min sign 3 8 8 8 8 6000 count 0 to 5999 measurement reading with 61 segments 4 AUTO Autorange mode 5 REL Relative mode 6 Diode test mode 7 Audible continu ty 8 HOLD Data hold mode 9 oC oF m V A K M...

Страница 22: ...8 2 digits 6 000 VDC 1 5 2 digits 60 00 VDC 600 0 VDC AC voltage 50 400 Hz 6 000 VAC 1 8 8 digits 60 00 VAC 600 0 VAC Resistance 600 0 1 0 4 digits 6 000 K 1 5 2 digits 60 00 K 600 0 K 6 000 M 2 5 3 d...

Страница 23: ...ge 50 400 Hz VAC Operating temperature 5 o C 40 o C 40 o F 104 o F Storage temperature 20 o C 60 o C 4 o F 1404 o F Operating humidity Max 80 up to 31 o C 87 o F decreasing linearly to 50 at 40 o C 10...

Страница 24: ...0 ADC 600 ADC 1000 AAC or 600 AAC range 2 If the range of the measured is not known select the higher range first then move to the lower range if necessary 3 Press the trigger to open jaw Fully enclos...

Страница 25: ...ltage measurement on the LCD display 4 4 Frequency duty cycle measurements electronic 1 Set the rotary function switch to V position 2 Select ACV with the MODE button 3 Press the Hz button to indicate...

Страница 26: ...For Resistance tests read the resistance on the LCD display 4 6 Diode and Continuity measurements 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug...

Страница 27: ...tested 5 Read the capacitance value in the display 4 8 Temperature measurements WARNING To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measu...

Страница 28: ...tion 1 Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet 2 If AC voltage is present the detector light will illuminate NOTE The conductors in electrical cor...

Страница 29: ...To freeze the LCD meter reading press the data hold button The data hold but ton is located on the left side of the meter top button While data hold is active the HOLD display icon appears on the LCD...

Страница 30: ...lay and is used when the ambient light to too low to permit viewing of the displayed readings Press the button for two seconds to turn the backlight on and press the button a second time to turn the b...

Страница 31: ...31 www nieaf smitt com...

Страница 32: ...32 www nieaf smitt com...

Отзывы: