IMPORTANT INFORMATION
A
Due to allowable operating temperature of accumulator
charging valve avoid contact or burn injury may occur.
B
Be sure system energy is relieved from accumulator
charging valve before removing from machine. See
machine operating instructions for procedures to relieve
system energy.
C
Relief valve is preset at the factory. DO NOT READJUST
or system damage or failure may occur.
D
Do not exceed the high limit pressure setting indicated
in TABLE 1 and TABLE 2 or system damage or failure
may occur.
This document is intended to provide general information about MICO Products. MICO, Inc. has attempted to present accurate information about MICO Products
in its catalogs, brochures, and other printed materials. MICO, Inc. is not responsible for errors, inaccuracies, or inconsistencies that may exist in any catalog,
brochure, or other printed materials or any damages arising from or related to reliance on information in them. Materials and specifications for MICO Products set
forth in catalogs, brochures, and other printed materials are subject to change without notice or obligation. Refer to www.mico.com for the most recent versions of
our literature. If you have any questions concerning MICO Products, please contact MICO, Inc. All MICO Products and service are sold and provided subject to the
MICO Warranty at www.mico.com in effect on the date of sale or supply.
MICO is a trademark and registered trademark of MICO, Inc. MICO is registered in the U.S. Patent and Trademark Office as well as in Australia, Canada, Indonesia, Japan, Peoples Republic of China, South Korea, and the European Community.
MICO, Inc.
1911 Lee Boulevard / North Mankato, MN U.S.A. 56003-2507
Tel:
+1 507 625 6426
Fax:
+1 507 625 3212
Form No. 81-463-019
Revised 2017-06-01
www.mico.com
ACCUMULATOR
CHARGING VALVE
with Relief Valve
Product Explanation,
Operating Information,
and Service Instructions
ACV-DMO-RV
PRODUCT EXPLANATION
The accumulator charging valve is designed for installation
in an open center hydraulic system between the pump and
the downstream secondary hydraulic devices.
The accumulator charging valve supplies oil on demand to
the accumulator from the open center circuit. Accumulator
charging is accomplished at a preset rate (GPM) and is
relatively constant within the preset pressure limits.
The flow to the downstream secondary hydraulic devices will
be reduced fractionally for a short time when the accumulator
is charging. This does not noticeably affect the operation of
these components. Full system pressure is available to the
downstream secondary hydraulic devices at all times provided
oil delivery and pressure from the pump is not impeded.
The accumulator charging valve incorporates a full flow
relief valve to limit the maximum pressure in the hydraulic
system.
The accumulator upper and lower pressure limits, charging
flow rate, and the relief valve setting are set at the time of
manufacture.
OPERATING INFORMATION
End user must provide proper maintenance of valve, should
it become inoperable, by replacing the valve or servicing it
with the proper repair kit. See TABLE 1 on page 3 or TABLE 2
on page 5 for the proper repair kit number. Observe service
instruction procedures on following pages. See Warnings A, B,
C, and D below.
Содержание MICO ACV-DMO-RV
Страница 7: ...Form No 81 463 019 Revised 2017 06 01 7 MICO Inc NOTES...