7
SySTeMS aND feaTUReS
floor System (cont.)
CAUTION:
Inspect all floor system components prior to
loading and unloading.
Prior to loading or unloading, verify there are:
– No delaminated and/or broken wood boards
– No deformed, cracked, or wavy aluminum boards
– No missing or loose fasteners in decking or base-rail
connections
– No bent and/or cracked crossmembers
– No cuts or structural damage on lower section of
sidewalls
• Do not damage or compromise the integrity of the
floor with excessive nailing in a localized region.
• Use of dock boards and leveling equipment is
recommended for forklift entry.
• Do not expose the floor or body components to
corrosive materials and solvents. Transporting
corrosives may void the warranty.
• All flooring repairs must be performed using
materials with identical section properties,
thickness, and type/specification of wood or
aluminum.
floor System (cont.)
High-Capacity Floor System:
Only Wabash National’s High-Capacity Floor
System is rated at 35,000 pounds. All other
Wabash National flooring systems are rated at
lower load rating capacities.
Any trailer with a High-Capacity Floor System is
marked and identified on both the exterior and
interior walls of the trailer. The decal below is
displayed on the rear interior wall of any trailer
having a High-Capacity Floor System.
!