Before installing this heater, please read all the enclosed instructions carefully and 

follow any recommendations regarding installation and use.

Electrical installation

The HC range comprises 1, 2 and 3 ceramic element models:

• One  and  two  ceramic  single  phase  230V  heaters  are  factory  fitted  with  high 

temperature  silicon  rubber  flexible  cable  conforming  to  BS  6500  having  a 

temperature rating of 180°C continuous (H05SS-F).

• Three ceramic  heater  models  are  supplied  without  cables,  and  configured  for 

single phase 230V operation. They can be converted to 3 phase and neutral 400V 

by removing the two red wires under the right hand cover. For connection use only 
silicon rubber flexible cable conforming to BS 6500 having a temperature rating of 

180

°

C (H05SS-F).

• The heaters must be earthed.
• To prevent nuisance tripping use type C MCBs. In multi-heater installations spread 

the heaters over several circuits.

The  heater  is  supplied  with  a  wall  mounting  bracket  ready  for  attachment  to  the 

heater. Place the heater face down and attach one 'U' bracket to back. Make sure 

cable gland is towards the bottom of the heater

movement

Location
• Heaters should be angled at 30° to 45° from the vertical, and never straight down.
• There must always be a minimum clearance of 450mm between the top of the

heater and the ceiling.

Wall mounting
• Decide  whether  vertical  movement  only  (Diagram  A)  or  vertical/horizontal 

movement (Diagram B) is required for correct positioning of heaters and assemble 

as shown.

• Avoid mounting heaters on structures liable to vibrate.
• Recommended  mounting  heights  and  safety  distances  should  always  be 

observed.