General Instructions

Please read these instructions carefully before installation and 

use, and keep them for future reference.

Application area

The FEZ336 has three heating panels and is designed for 

mounting heights of between 4 and 12 metres.

FEZ336 can be used both for total or supplementary heating of 

whole premises, and also for spot or zone heating of parts of 

premises. 

Operating conditions 

The maximum surrounding temperature must not 30 

°C.

Do not install where explosive vapours may be present, as 

defined in BS 5345. Or in environments where there is an 

increased risk of fire.

FEZ336 are protected to IP44, and are intended for indoor use 

only.

Mounting 

The FEZ336 can be mounted on the ceiling, on armature rails, 

wire, or suspended from the ceiling by means of rods or chains. 

The units are intended for permanent installation and should 

always be mounted horizontally. 

In rooms which are frequently used, the heater should be 

mounted 1.5 to 2 metres above head height, see Fig. 2. 

The distance between the heaters should be less than the 

height between the heater and floor, i.e ”a” should be less than 

”H”, see Fig. 2. 

For minimum safety distances, see Fig. 3.

Mounting brackets are included and can be found inside the 

connection box.

1) Determine the position of the panel on the ceiling.

2)  Bend the "legs" of the brackets (fig 1.1) to approximately 90° 

(fig1.2). 

3)  Mount the brackets with an internal distance according to 

dimensional drawing page 2, on the ceiling or on a wire (fig 

1.3). 

    When the panel is mounted on a wire put the bracket on top 

of wire, and use clips to prevent the heater from sliding.

    Mount the heater according to fig 1.4, start with one end 

and then assemble the other one. Making sure that the 

screws are tight. 

Electrical installation

The F

EZ336 is designed for fixed installation.

The heater(s) should only be wired by a competent person and 

in accordance with the current edition of the IEE Wiring 

Regulations (BS 7671: Requirements for Electrical Installations) 

and any applicable statutory regulations.

The appliance should be preceded by an isolating switch 

preferably with a visual indicator.

The FEZ336 is approved for serial connection. Connection is 

made via the block terminals (16 mm²) which are located at the 

end of the heater.

There are are two holes for cable glands on the top of the 

connection box. The cable glands used must guarantee the 

protection class requirements. 

Installations protected by a Residual Current Device (RCD)

If the installation is protected by a Residual Current Deive 

(RCD) which trips when the heater is connected, this may be 

due to a build up of moisture in the heating element. 

This is easily rectified by connecting the heater without a RCD 

so that the elements dry out. The drying time can vary from a 

few hours to a few days.

As a preventative measure in very damp environments the 

heater should occasionally be run for a short time during the 

summer months

To prevent nuisance tripping of RCD's in large installations, the 

heaters should divided over several circuits each with its own 

RCD.

Maintenance

The heaters have no moving parts and regular maintenance is 

not required.

There might be a rattling noise the first few weeks of use while 

the heating panels settle, this is normal.

If the heater is used in rooms where aerosols, lacquer, solvents 

or similar are present, the aluminium panels may discolour. The 

output is not affected. 

Important safety notices
Do  not  touch  the  surfaces  of  the  heater  while  it  is 
operating, the surfaces are hot!

The heater must not be covered, as this will result in the 
risk of fire.

The minimum safety distances (Fig 3) must be adhered to.

Mounting and operating instructions

FEZ336 Overhead Radiant Heater

Please read these instructions fully before commencing installation and 

retain them for future reference

FEZ336 

 

3600w 

 

400V3N