background image

Fingertip

LED Light

When manually starting SpO2/BP/APG/ECG measurement, the red light will light up after 
touching your finger

LED lights

Orange

R:255 - 

G:160 - B:0

Flicker

Low battery ≤20%, flash once every 5 
minutes

Green

R:90

G:190

B:50

Flicker

Bracelet charging, flicker once every 1 
second

Always 

bright

Fully charged bracelet

Remove the charger light off

Light blue

R:0

G:160
B:220

Flicker

When requesting a measurement
(via smartphone), flicker once every 1 
second

Flicker

During blood oxygen/blood pressure/APG 
measurement: 1 - When the measure-
ment is initiated, it flashes once every 1 
second; 2 - When the fingertip covers the 
detection window, stop flashing (no light) 
to avoid affecting the data

Always 

bright

When the health measurement is complet-
ed, it is always on for 2 seconds

Red

R:230

G:0
B:0

Flicker

When the health measurement fails: Red 
Flicker (2 times for second)

Flicker

Guardian Alert: Flicker 10 seconds
(2 times for second), then fix for 2 seconds

Multicolor

RGB

Flicker

Power On: Soft fast transition between all 
spectre colors (1/4 second per color) until 
at the switch on

Power Off: Soft slowly transition between 
all spectre colors (1 second per color) until 
shutdown

White

R:255
G:255
B:255

Always 

bright

To verify if the device is on. Click once 
the button and a white light be on for 2 
seconds.

LED LIGHT STATUS

Содержание BioSense

Страница 1: ...BioSense health smartband QUICK START GUIDE ...

Страница 2: ...BioSense health smartband 1 Packing List The box contains the following items BioSense smartband USB C cable Charging Base Card info ...

Страница 3: ......

Страница 4: ...nto the charger base socket 2 Put the BioSense onto the charging base and align the metal contacts on the back of the smartband with the gold pins on the charging base while placing the device and the charger will line up with magnets in the right direction 3 Place the charger on the deck with the BioSense sideways 1 ...

Страница 5: ...2 3 ...

Страница 6: ... on an iPad you need to select iPhone only when down loading it from the App Store 7 Compatibility Support Support Android 5 0 or above iOS 10 0 or above 8 Connection After finishing the download open the App and register an account then complete the connection process according to the operating instructions on the App NOTE In order to successfully connect a phone to the smartband you need to turn...

Страница 7: ...1 2 4 2 3 5 1 2 3 4 5 Power ON button ECG BIA electrodes LED light BP SpO2 APG sensor VYVO Pay chip inside ...

Страница 8: ...oring In order to monitor heart rate more accurately please wear the smartband approximately one finger away from the wrist bone NOTE BioSense is only lor swimming lf you wear BioSense lor diving it may cause damage to the device Such damage is not within the scope of the warranty ...

Страница 9: ...under cold water 2 BioSense does not have a waterproofing effect on seawater acid and alkaline solution chemical reagents and other corrosive liquids lf inadvertently encounter or contact with corrosive liquid please clean with clear water and dry the device The damage caused due to improper use or abuse of the devi ce is not within the scope of the warranty ...

Страница 10: ...Q PDJQHW DGVRUSWLRQ 2 Heart electrode stainless steel 316L pvd gold 3 Bottom shell PA embedded 2 pieces of 316L stainless steel PVD 2PCS POGO pin Basic VSHFLҩFDWLRQ size weight color black white Hardware VSHFLҩFDWLRQ built in storage RAM 256KB ROM 1Mbit external 8MB APP iOS 10 0 or above Android 5 0 or above display resolution button touch button Connection bluetoth BLE 5 0 WIFI NFC support ...

Страница 11: ...ss ECG BIA APG Blood Pressure Blood Oxygen Arrhythmia Detection Temperature Sleep Activity data steps calories standing Guardian heart rate respiratory rate blood pressure blood oxygen temperature atrial ҩEULOODWLRQ Other data waterproof level IP68 charging time 2 hours strap size 140 200 mm prototype length plus or minus 5 mm strap material liquid silicone ...

Страница 12: ...pport manual measurement app initiated Stress Support 24 hour automatic measurement the automatic measurement interval is 1 hour and the measurement is on the whole point Support manual measurement app initiated BP Connect APP for blood pressure calibration Support 24 hour automatic measurement the automatic measurement interval is 1 hour and the measurement is on the whole point Support manual me...

Страница 13: ...K VLGHV ZLWK WKH LQGH ҩQJHU and thumb respectively and the left and right hands cannot touch each other the measurement precautions are written on the APP and the operation gesture diagram is attached Touch button Long Press 10 seconds ON Soft fast transition between all spectre colors 1 4 second per color until at the switch on 3 seconds Broadcast The bracelet enters the broadcasting state red DQ...

Страница 14: ...d it flashes once every 1 second 2 When the fingertip covers the detection window stop flashing no light to avoid affecting the data Always bright When the health measurement is complet ed it is always on for 2 seconds Red R 230 G 0 B 0 Flicker When the health measurement fails Red Flicker 2 times for second Flicker Guardian Alert Flicker 10 seconds 2 times for second then fix for 2 seconds Multic...

Страница 15: ...r 5 Avoid extreme shock and harsh treatment of the device as it may reduce device product life 6 Do not expose the device to extreme temperatures that are either too cold or too hot for an extended period of time which may cause permanent damage 7 After each training session please rinse the smartband with clean water Cleaning the device Even the laintest prolonged exposure to sweat or moisture ma...

Страница 16: ...n circumstances including the user s physical characteristics installation of the device and type intensity of activity The activity trackers rely on sensors to track your movement and other metrics The data and information provided by the device are intended to assess your activity and metrics closely but may not be completely accurate including the data for steps sleep distance heart rate and ca...

Страница 17: ...h velocity water or submersion below shallow depth 2 Unless otherwise specified VYVO BioSense and relateci services are not medical devices and are not intended to diagnose treat cure or prevent any disease With regard to accuracy VYVO has developed products and services to track certain wellness information as accurately as reasonably possible The accuracy of VYVO s products and services is not i...

Страница 18: ...Thank you ...

Страница 19: ...TIK OT G XKYOJKTZOGR OTYZGRRGZOUT NOY KW OVSKTZ MKTKXGZKY YKY GTJ IGT XGJOGZK XGJOU LXKW KTI_ KTKXM_ GTJ OL TUZ OTYZGRRKJ GTJ YKJ OT GIIUXJGTIK OZN ZNK OTYZX IZOUTY SG_ IG YK NGXSL R OTZKXLKXKTIK ZU XGJOU IUSS TOIGZOUTY U K KX ZNKXK OY TU M GXGTZKK ZNGZ OTZKXLKXKTIK ORR TUZ UII X OT G VGXZOI RGX OTYZGRRGZOUT L ZNOY KW OVSKTZ JUKY IG YK NGXSL R OTZKXLKXKTIK ZU XGJOU UX ZKRK OYOUT XKIKVZOUT NOIN IGT...

Отзывы: