background image

RAIN-PRO VYR PG-6045

Irrigation Programmer

Installation Instructions,

Programming and Operation.

Содержание RAIN-PRO VYR PG-6045

Страница 1: ...RAIN PRO VYR PG 6045 Irrigation Programmer Installation Instructions Programming and Operation ...

Страница 2: ...Head Quarter Office Polígono Industrial N 1 Monte de la Abadesa Parcela 3801 09001 BURGOS ESPAÑA P O Box 313 Tel 34 947 26 22 26 Fax 34 947 26 21 24 www vyrsa com e mail vyrsa vyrsa com ISO 9001 2000 ...

Страница 3: ...ction 3 4 Set time 3 5 Set start times 4 6 Set watering days 5 7 Set stations run times 6 8 Set auxiliaries 7 8 9 Test system 9 10 Run program manually 10 11 Shut off controller 10 12 Auto run mode 11 CUSTOMER SERVICE 13 Technical Support 12 14 Waranty 12 15 Solutions for troubleshooting 13 INDEX INDEX ...

Страница 4: ...ding power for both controller and electromagnetic valve C Common terminal Common terminal for rain sensor and electromagnetic solenoid valve R Rain sensor terminal usually it will not to be connected with C terminal Rain sensor will interrupt when raining 1 11 Connection for 24Vac solenoid valve of each station 1 INSTALLATION SPECIFICATIONS 1 SET UP ...

Страница 5: ...connected outside and it will be interrupted during raining On off function for rain sensor DELAYS BETWEEN MASTER VALVE MV OR PUMP STATIONS Synchronization between water pump and station While the magnetic valve starting the water pump will be put into operation simultaneously or with a delay MASTER VALVE MV OR PUMP Water pump will be put into operation simultaneously WATER BUDGET Allow quick adju...

Страница 6: ...urrent time correct day Press or to adjust the hours Using press adjust the minutes After clock was set press twice to adjust the calendar Date will be year month day and week odd even day display automatically during adjusting Press will return clock 4 SET TIME FUSE BATTERY 9V COMMON SENSOR POWER TRANSFORMER 220V 24 VAC MASTER VALV VALVES ...

Страница 7: ...rammable group START NO corresponding to schedule of each program Using o will move to relevant setting After 6 start time for PROG NO 1 were finished press P to select PROG NO 2 for next schedule Total 6 programmable group will be set by same way If less than 6 starting time needed it can be cancelled by press or up to display OFF during setting hours 5 SET START TIMES ...

Страница 8: ... moving ODD will display as odd day and EVEN as even day watering on odd day or even day can be selected Using to interval days watering selection press or under NO WATER will make a selection how may day will begin watering under INTERVAL DAYS Using to set INTERVAL DAYS press or button to select interval days After PROG NO 1 finishing press P for PROG NO 2 interval days setting and the rest to be...

Страница 9: ... each station Station No show relevant station Press or and or to set running time for selected station The RUN TIME can be set to 0 00 if watering not need After 1 6 points for this STATION NO finished press P to set running time of each points of following station 7 SET STATIONS RUN TIMES ...

Страница 10: ...tation SENSOR DELAY The station 1 will be displayed first to make selection for if rain sensor controlling needed using then press or selecting ON or OFF press ON then using twice to set delay time from 0 to 240 hours of rain sensor This mean a specific delay time after the rainy sensor with an indication of dried out and the watering of relevant station will be closed after this delay Using retur...

Страница 11: ...r PUMP DELAY Press P button again into PUMP DELAY BETWEEN to select delay time that is the time lags between the pump begin working and the relevant station It can be set from OFF to 99 seconds STATION DELAY Press P into STATION DELAY this mean delay time among each station If 10 seconds were set this station will start running 10 seconds later than former station stop The others will be set as sa...

Страница 12: ...om of the Led During operation press P button again which can stop manual running Press and at same time the multi will display in the left bottom of the led This mean it can be run continually once for manual setting time of more stations Press or select station using then press or again to set running time press again to return station selection After run time for each station to be set pressing...

Страница 13: ...ton select programs No and press or button to make relevant program ON or OFF after 6 programs to be set press button the program with ON will running and press P button the operation will be halt for 10 minutes The HOLD 10 00 will be displayed press P again the running will renew After manual programs running the system will return to automatic running status 10 RUN PROGRAM MANUALLY 11 SHUT OFF C...

Страница 14: ... to be installed from step No 2 to No 6 During automatic running press will indicate current date press will return clock status Under clock status and press the flow of irrigation can be adjusted 10 to 200 by press button or This mean the running time can be shorten or extended proportionally under all parameter no change to adapt the requirement in different season 12 AUTO RUN MODE ...

Страница 15: ...ents or replacement of any of our products or part that results from misuse negligence alteration tampering modification or improper installation and or maintenance of the product This warranty extends only to the original installer of the VYRSA product In case that a defect appears in a VYRSA product or part during the warranty period you should contact your local VYRSA Authorized Distributor VYR...

Страница 16: ...in ON Make sure that the cable or the positive or negative poles are not broken Make sure you are using 24Vac solenoids Make sure the wires are properly connected The distance in between the controller and the solenoids must not be more than 300 meters Check the technical especifications of the solenoids that you are using or ask our tech department Make sure the solenoids are clean in the inside ...