![Vynco VLWLED4 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/vynco/vlwled4/vlwled4_installation-instructions-manual_1058022004.webp)
INSTALLATION INSTRUCTIONS AND SPECIFICATIONS
for VLWLED4 range of Weatherproof Fixtures
Vynco Industries (NZ) Ltd Phone +64 3 379 9283 or +64 9 525 6051
www.vynco.co.nz
EMERGENCY FITTING
Run Time:
3 hours
Battery pack type:
Lithium Ion 12-volt 4400mAH
Temperature range:
-20°C to +40°C
Emergency light output: 30%
INSTALL PROCEDURE
For emergency fitting follow the wiring diagram below.
WIRING DIAGRAM
SW A = Switched active/ Emergency controller phase
A = Live or Phase
E = Earth
N = Neutral
This fitting is desitgne for permanent connection.
24 hour charging period is required before the
emergency feature can be used.
ONCE THE WIRING HAS BEEN COMPLETED,
CONNECT THE BATTERY PACK TO THE
EMERGENCY CONTROLLER.
TEST PROCEDURE
1. (A) Phase is off
2. (SW A) Phase is live
3. Remove the clear cover
4. The green LED indictor will be on
5. Press the TEST BUTTON to test the function on
the light, the light will remain on while the TEST
BUTTON is pressed and the green LED indictor will
turn off while the TEST BUTTON is pressed
Complies with AS/NZS 60598.2.22