![Vynco VAF16 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/vynco/vaf16/vaf16_installation-instructions_1058014002.webp)
INSTALLATION INSTRUCTIONS
VYNCO.CO.NZ
INSTALLATION PROCEDURE
STEP 1
The preferred method is to mount the fan base onto
a solid surface, in the roof space at least 2.3m above
the floor, by screwing it to the timber trusses. Use at
least No. 6 x 1/2 inch screws.
STEP 2
Keep the fan at least 50mm away from
surrounding structures.
STEP 3
Attach 150mm ducting onto each end of the fan
using duct tape.
STEP 4
Make sure the ducting is not impeding the fan blade.
The duct should be pulled tight and cut to length,
and connected to the internal grille and external
grille, otherwise the performance of the fan will
be affected.
STEP 5
Attach the fan to the mounted fan base. Ensure all
4 snap hooks are secured correctly. Plug the fan into
a power point.
182.0
Protect tabs
in packaging
Protect tabs
in packaging
301.0
Protect tabs in
packaging
175.0
A
DETAIL A
SCALE 1 : 2
REVISIONS
REVISION
DATE
FINISH:
MATERIAL:
REVISION:
DESCRIPTION:
SHEET 1 OF 1
A3
SIZE
APPROVED BY:
PART No:
388 Tuam St
Christchurch
New Zealand
P:
03 379 9283
W:
vynco.co.nz
UNLESS OTHERWISE STATED ALL DIMENSIONS ARE IN MILLIMETRES
ALL CRITICAL TOLERANCES SPECIFIED IN DRAWING
NON SPECIFIED TOLERANCES:
LINEAR: 0.0 ±0.5 0.00 ±0.1 ANGULAR: ±0.5°
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VYNCO INDUSTRIES
(N.Z.) LTD. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION
OF VYNCO INDUSTRIES (N.Z.) LTD IS PROHIBITED.
DRAWN BY:
DRAWN DATE:
CHANGE BY:
CHANGE DATE:
APPROVED DATE:
-
-
-
-
-
-
-
koopsq
9/20/2019
-
-
9/20/2019
koopsq
DRAWING NOT TO SCALE
110.0
208.0 OVERALL
175.0 OVERALL
153.6
296.0 OVERALL
172.0
3
1
1
3
2
4
5
Note:
Fan assembly including flexible cable and plug (ITEM NO. 4)
supplied by third party.
REVISIONS
REVISION
DATE
-01
19-02-2019
First release
-02
19-06-2019
Prototype prerelease to H&G
-03
29-07-2019
Change fan design to suit H&G EC fan
-04
29-07-2019
Added note for supplier.
A
09-09-2019
PRODUCTION RELEASE
SPECIFICATIONS
VOLTAGE [VAC at 50/60 Hz]
220-240
POWER [W]
~18
CURRENT [A]
0.14
AIRFLOW @ 0 Pa [m3/h]
>400
RPM
TBC
DUCT SIZE [mm]
150
CLIMATE CLASS
T
NOISE LEVEL @ 3m [dBA]
<38 dBA
IP (INSTALLED)
IP44
INTERNAL TERMAL
PROTECTION
MANUAL RESET
BEARING TYPE
626Z Deep groove
ball bearing
ITEM NO.
PartNo
DESCRIPTION
QTY.
1
24336-104
F16 SPIGOT
2
2
24336-003
F16 Mounting Plate
1
3
-
M4 x 16 PAN HEAD SCREW
CROSS
8
4
-
17251 EC MOTOR
1
5
454
M4 NUT
8
FINISH:
MATERIAL:
REVISION:
DESCRIPTION:
SHEET 1 OF 1
A3
SIZE
APPROVED BY:
PART No:
388 Tuam St
Christchurch
New Zealand
P:
03 379 9283
W:
vynco.co.nz
UNLESS OTHERWISE STATED ALL DIMENSIONS ARE IN MILLIMETRES
ALL CRITICAL TOLERANCES SPECIFIED IN DRAWING
NON SPECIFIED TOLERANCES:
LINEAR: 0.0 ±0.5 0.00 ±0.1 ANGULAR: ±0.5°
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VYNCO INDUSTRIES
(N.Z.) LTD. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION
OF VYNCO INDUSTRIES (N.Z.) LTD IS PROHIBITED.
DRAWN BY:
DRAWN DATE:
CHANGE BY:
CHANGE DATE:
APPROVED DATE:
A
-
DRAFT
24336-000
F16 AXIAL FAN ASSY
koopsq
9/9/2019
K
09/09/2019
2/19/2019
koopsq
DRAWING NOT TO SCALE
VAF16 - IN-LINE AXIAL FAN