Vynco VAF16 Скачать руководство пользователя страница 2

INSTALLATION INSTRUCTIONS

VYNCO.CO.NZ

INSTALLATION PROCEDURE

STEP 1 
The preferred method is to mount the fan base onto 
a solid surface, in the roof space at least 2.3m above 

the floor, by screwing it to the timber trusses. Use at 
least No. 6 x 1/2 inch screws.

STEP 2
Keep the fan at least 50mm away from 
surrounding structures.

STEP 3
Attach 150mm ducting onto each end of the fan 
using duct tape.

STEP 4
Make sure the ducting is not impeding the fan blade.
The duct should be pulled tight and cut to length, 

and connected to the internal grille and external 

grille, otherwise the performance of the fan will 
be affected.

STEP 5
Attach the fan to the mounted fan base. Ensure all 
4 snap hooks are secured correctly. Plug the fan into 
a power point.

 182.0 

Protect tabs

in packaging

Protect tabs

in packaging 

 301.0 

Protect tabs in

packaging

 175.0 

A

DETAIL A

SCALE 1 : 2

REVISIONS

REVISION

DATE

FINISH:

MATERIAL:

REVISION:

DESCRIPTION:

SHEET 1 OF 1

A3

SIZE

APPROVED BY:

PART No:

388 Tuam St

Christchurch

New Zealand

P:

    03 379 9283

W: 

vynco.co.nz

UNLESS OTHERWISE STATED ALL DIMENSIONS ARE IN MILLIMETRES

ALL CRITICAL TOLERANCES SPECIFIED IN DRAWING

NON SPECIFIED TOLERANCES: 

LINEAR:  0.0 ±0.5    0.00 ±0.1     ANGULAR:  ±0.5°

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VYNCO INDUSTRIES 

(N.Z.) LTD.  ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION 

OF VYNCO INDUSTRIES (N.Z.) LTD IS PROHIBITED.

DRAWN BY:

DRAWN DATE:

CHANGE BY:

CHANGE DATE:

APPROVED DATE:

-

-

-

-

-

-
-

koopsq

9/20/2019

-
-

9/20/2019

koopsq

DRAWING NOT TO SCALE

 110.0 

 208.0 OVERALL 

 175.0 OVERALL 

 

153.6 

 296.0 OVERALL 

 172.0 

3

1

1

3

2

4

5

Note:

Fan assembly including flexible cable and plug (ITEM NO. 4)

supplied by third party.

REVISIONS

REVISION

DATE

-01

19-02-2019

First release

-02

19-06-2019

Prototype prerelease to H&G

-03

29-07-2019

Change fan design to suit H&G EC fan

-04

29-07-2019

Added note for supplier.

A

09-09-2019

PRODUCTION RELEASE

SPECIFICATIONS

VOLTAGE [VAC at 50/60 Hz]

220-240

POWER [W]

~18

CURRENT [A]

0.14

AIRFLOW @ 0 Pa [m3/h]

>400

RPM

TBC

DUCT SIZE [mm]

150

CLIMATE CLASS

T

NOISE LEVEL @ 3m [dBA]

<38 dBA

IP (INSTALLED)

IP44

INTERNAL TERMAL 

PROTECTION

MANUAL RESET

BEARING TYPE

626Z Deep groove 

ball bearing

ITEM NO.

PartNo

DESCRIPTION

QTY.

1

24336-104

F16 SPIGOT

2

2

24336-003

F16 Mounting Plate

1

3

-

M4 x 16 PAN HEAD SCREW 

CROSS

8

4

-

17251 EC MOTOR

1

5

454

M4 NUT

8

FINISH:

MATERIAL:

REVISION:

DESCRIPTION:

SHEET 1 OF 1

A3

SIZE

APPROVED BY:

PART No:

388 Tuam St

Christchurch

New Zealand

P:

    03 379 9283

W: 

vynco.co.nz

UNLESS OTHERWISE STATED ALL DIMENSIONS ARE IN MILLIMETRES

ALL CRITICAL TOLERANCES SPECIFIED IN DRAWING

NON SPECIFIED TOLERANCES: 

LINEAR:  0.0 ±0.5    0.00 ±0.1     ANGULAR:  ±0.5°

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VYNCO INDUSTRIES 

(N.Z.) LTD.  ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION 

OF VYNCO INDUSTRIES (N.Z.) LTD IS PROHIBITED.

DRAWN BY:

DRAWN DATE:

CHANGE BY:

CHANGE DATE:

APPROVED DATE:

A

-

DRAFT

24336-000

F16 AXIAL FAN ASSY

koopsq

9/9/2019

K

09/09/2019

2/19/2019

koopsq

DRAWING NOT TO SCALE

VAF16 - IN-LINE AXIAL FAN

Отзывы: