![VYKING FORCE VF2200IG Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/vyking-force/vf2200ig/vf2200ig_instruction-manual_1057978047.webp)
47
2.5kVA Inverter Generator VF2200IG
Table 1: Standard Valve Lash
Intake Valve
Exhaust Valve
Valve Lash
.0023-.0039in
(.06-.10mm)
.0031-.0048in
(.08-.12mm)
Bolt Torque
8-12N.m
8-12N.m
6. If an adjustment is required, hold the adjusting nut and loosen the jam nut.
7. Turn the adjusting nut to obtain the correct valve lash. When the valve lash is
correct, hold the adjusting nut and tighten the jam nut to 106 in-lb (12 N•m).
8. Recheck the valve lash after tightening the jam nut.
9. Perform this procedure for both the intake and exhaust valves.
10. Install the rocker arm cover, gasket and spark plug.
Cleaning the inverter
It is important to inspect and clean the inverter before every use. Clean All Engine Air
Inlet and Outlet Ports – Make sure all engine air inlet and outlet ports are clean of any
dirt and debris to ensure the engine does not run hot.
Figure 20
(1) Valve, (2) Feeler Gauge Area
(3) Rocker Arm, (4) Jam Nut, (5) Adjusting Nut
1
2
3
4
5
Содержание VF2200IG
Страница 58: ...58...
Страница 59: ...59 2 5kVA Inverter Generator VF2200IG...