Vxl Winlinx Lite Скачать руководство пользователя страница 4

Winlinx -V8 Thin Client Family  Hardware User's Guide

iv

FEDERAL COMMUNICATION COMMISSION (FCC) STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the Instructions, may cause harmful interference to radio
communications, however there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment OFF and ON, the user is encouraged to try
to correct the interference by one or more of the following measures:
a.

 

Re-orient or relocate the receiving antenna.

b.

 

Increase the separation between the equipment and receiver.

c.

 

connect the equipment  into an outlet on a circuit different from that to which the
receiver is  connected.

d.

 

consult the dealer or an experienced radio / television technician for help.

e.

 

Ensure that all expansion slots (on the back or side of the computer) are covered
with metal retaining brackets, and  tightly attached to the computer cabinet.

Each Thin Client is equipped with a FCC compliance label that shows only the FCC
identification number. The full information of the associated label is as follows:

This device complies with Part 15 of the FCC rules.  Operation is subject to the
following two conditions:

1.

this device may not cause harmful interference, and

2.

this device must accept any interference received, including 
interference that may cause undesired operation.

WARNING

 

Only equipment certified to comply with Class B (computer input/output
devices, terminals, printers etc.) should be attached to this equipment, and
must have shielded interface cables.

 

Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.

 

This equipment should not be used in electro-medical applications.

 

There are no user serviceable parts inside.
DO NOT disassemble  the equipment  as this can nullify your warranty

 

DO NOT operate this equipment in corrosive or explosive atmosphere.

 

DO NOT operate this equipment outside specified temperature limits.

Содержание Winlinx Lite

Страница 1: ...Winlinx Winlinx V8 Thin Client Family Thin Client Family Hardware User s Guide...

Страница 2: ......

Страница 3: ...d does not represent a commitment on the part of the manufacturer No part of this manual may be reproduced or transmitted in any form or means electronic or mechanical including photocopying and recor...

Страница 4: ...t the dealer or an experienced radio television technician for help e Ensure that all expansion slots on the back or side of the computer are covered with metal retaining brackets and tightly attached...

Страница 5: ...inx Pro Netica 3 INSTALLATION SITE REQUIREMENTS 5 PRECAUTIONS SAFETY REQUIREMENTS 5 WALL MOUNTING 6 CONNECTING THE THIN CLIENT 6 Rear Panel Overview 7 TYPICAL INSTALLATIONS 8 TROUBLE SHOOTING 10 SPECI...

Страница 6: ...100BASE T LAN Interface 16 Video Port 17 Mouse Keyboard Port 17 Audio Microphone Port 17 S Video Composite Video Port 17 LCD Port 18 Game Port 18 USB Port 19 CABLING REQUIREMENTS 19 10 100BASE T Cabli...

Страница 7: ...are essentially terminal devices that connect onto multi user application servers operating under the Citrix MetaFrame Citrix WinFrame and Windows NT operating system They communicate with the applic...

Страница 8: ...t The Thin Client family consists of Winlinx Pro Premium model Winlinx Lite Economy model Netica Browser Base model FEATURES OF WINLINX LITE The Thin Client utilizes an industry standard 200MHz Cyrix...

Страница 9: ...the optional features mentioned consult factory for details These options are not field upgradable In an endeavor to provide a better product to you the customer our Company pursues continuous develo...

Страница 10: ...Winlinx V8 Thin Client Family Hardware User s Guide 4 This page is intentionally left blank...

Страница 11: ...outlet A table or desk of suitable size for placing the Thin Client Suitable place for the Thin Client such that it can be kept nearest to the power outlet to provide user easy accessibility to the ou...

Страница 12: ...space When the unit is to be wall mounted the rubber bushes on the bottom side have to be removed as shown in the figure below CONNECTING THE THIN CLIENT Before connecting any cables ensure that the...

Страница 13: ...d on the back panel and corresponding external cable connection Connector Symbol Connection Cable IN power socket AC Power cord OUT power socket Monitor Power cord Monitor Video PS 2 Keyboard PS 2 Mou...

Страница 14: ...pplication server using the ICA 3 protocol It can be linked to the server by LAN connection through TCP IP Direct connection through RS232 Dial In remote connection through modem Note After proper con...

Страница 15: ...SS Thin Client Figure 6 Direct Connection through RS232 If Dial In Remote Connection through modem is desired connect RS232 straight cable from a Thin Client serial port to a supported modem which is...

Страница 16: ...sure that the fuse in the plug if fitted is working 2 Power LED glows but no display Check whether the monitor video cable is properly plugged 3 Mouse or Keyboard is not working Check whether the mous...

Страница 17: ...256MB Winlinx Pro Winlinx Lite 32MB Expandable upto 256MB Netica Expandability One ISA PCI expansion slot Winlinx Pro Netica Power Management VESA display power management ICA 3 or RDP client support...

Страница 18: ...ocket INTERFACE COM1 COM2 Serial Ports RS232C compatible operating at 115 2K baud maximum 10 100Base T Port LAN interface Printer Port Parallel Centronics compatible 25 pin D type female Mouse Keyboar...

Страница 19: ...8 Thin Client Family Hardware User s Guide 13 USB Port USB Devices Game Port Joystick LCD Port TFT LCD panel Note Some of the interfaces may be optional depending on the model For more details refer C...

Страница 20: ...Winlinx V8 Thin Client Family Hardware User s Guide 14 This page is intentionally left blank...

Страница 21: ...t connectors Refer to the chapter INSTALLATION for the location of the connectors on the back panel COM1 COM2 Ports 9 Pin D Type Male Connector Pin Signal Description 1 DCD Data Carrier Detect 2 RXD R...

Страница 22: ...e 16 Printer Port Parallel 25 Pin D type Female connector Pin Signal 1 STROBE 2 9 DATA 0 7 10 ACKNOWLEDGE 11 BUSY 12 PAPER END 15 ERROR 18 25 GROUND 10 100BASE T LAN Interface RJ 45 Modular 8 pin jack...

Страница 23: ...eturn GND 13 Horizontal Sync 4 No Connection 9 No Connection 14 Vertical Sync 5 GND 10 No Connection 15 No Connection Mouse Keyboard Port PS 2 Mouse Keyboard Connector Pin Signal Pin Signal 1 Mouse KB...

Страница 24: ...Pin Signal Pin Signal 1 TX1 7 GND 15 TX0 2 TX1 8 VCC 16 TX0 3 4 AGND 11 TX2 19 DATA 5 TXC 12 TX2 20 CLOCK 6 TXC 13 14 AGND Game Port 15 Pin D type Female connector Pin Signal Pin Signal 1 2 VCC 10 RC3...

Страница 25: ...A Receptacle Pin Signal 1 VCC 2 D 3 D 4 GND CABLING REQUIREMENTS 10 100BASE T Cabling Cross Connection Without Hub Straight Connection With Hub TXD 1 3 RXD TXD 2 2 TXD RXD 3 1 TXD RXD 6 6 RXD RJ45 Pi...

Страница 26: ...ls are to be converted to 25 pin connector The diagram below shows their respective connections 9 Pin to 25 Pin Cross Connection 9 Pin to 25 Pin Straight Connection 7 4 3 5 1 2 6 8 4 20 2 7 8 3 6 5 9...

Страница 27: ...entronics parallel cable Some manufacturers have changed pin functions or polarity on their printers for such printers custom cables may be necessary For details refer to your printer manual for inter...

Отзывы: