VXI Technology, Inc.
38
SVM2608 Programming
Trigger Delay (0x1A, 0x42, 0x6A, 0x92, 0xBA, 0xE2) — Read & Write
D15 – D0
DELAY15 – 0
Trigger Delay
- The trigger delay value is used to set the time between
trigger occurrence and storing of data.
Minimum Value = 0
Maximum Value = 2
32
– 1
Timeout (0x1C, 0x44, 0x6C, 0x94, 0xBC, 0xE4) — Read & Write
D15 – D13
TOSEL2 – 0
Timeout Select
- This sets the resolution of the timeout counter. It will
determine how long the device waits between start and trigger events
before setting the timeout status bits.
000 - 10
μ
s
001 - 100
μ
s
010 - 1 ms
011 - 10 ms
100 - 100 ms
101 - 1.0 s
110 - 10.0 s
111 - 100.0 s
D12 – D0
TO12 – 0
Timeout Counter Setting
- This value multiplied by the timeout select
value yields the actual timeout setting.
Interrupt Enable (0x1E, 0x46, 0x6E, 0x96, 0xBE, 0xE6) — Read & Write
D15 – D0
IM15 – 0
Interrupt Enable
- Enables or disables interrupt generation for
corresponding bit in the interrupt status register.
0 = Disabled
1 = Enabled
P
on
state = 0
Interrupt Status (0x20, 0x48, 0x70, 0x98, 0xC0, 0xE8) — Read Only
D15 – D0
INT15 – 0
Interrupt Status Register
- If a corresponding bit in the interrupt enable
register is set, these bits indicate if an interrupt occurred. Otherwise, they
operate as status bits.
15 - Real time trigger input value
14 - This bit is reserved for future use
13 - This bit is reserved for future use
12 - Settled (range change ready)
11 - Result ready
10 - FIFO overrun
9 - FIFO underrun
8 - FIFO @ threshold
7 - ARM not ready - ERROR if ARM too soon (warning)
6 - Triggered - cleared when acquisition is complete
5 - Capture Complete
4 - Function busy
3 - Self test busy
2 - Self test passed
1 - CMD error
0 - Timeout occurred
Содержание SVM2608
Страница 2: ...VXI Technology Inc 2 ...
Страница 10: ...VXI Technology Inc 10 SVM2608 Preface ...
Страница 22: ...VXI Technology Inc 22 SVM2608 Introduction ...
Страница 54: ...VXI Technology Inc 54 SVM2608 Programming ...
Страница 56: ...VXI Technology Inc 56 SVM2608 Appendix A ...