VWR FS-RFC-30 Скачать руководство пользователя страница 1

Part number 20057, Rev 0 

 

 

 

 
 
 

 

 
 
 
 
 
 

FLAMMABLE STORAGE REFRIGERATORS, FREEZERS, & DUAL-TEMP UNITS 

MODELS FSR-1404, FSR-1704, FSR-2004, FSR-3004,  

FSF-1420, FSF-1720, FSF-2020, FSF-3020, FS-RFC-30 

(with options, “-DTD” Digital Temp Display, “-DA” CONTROL CENTER 

Temp Alarm and/or “-CR” Chart Recorder) 

OWNER’S INSTRUCTIONS 

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. 

READ THIS BOOK! 

Note to Customer: 

This  merchandise  was carefully packed and thoroughly inspected  before leaving our plant.  Responsibility for its 
safe  delivery  was  assumed  by  the  carrier  upon  acceptance  of  the  shipment.    As  directed  on  the  side  of  your 
packing carton, claims for loss or damage sustained in transit must be made on the carrier as follows: 
 
A.)

 

Visible Loss, Damage, Shortage External Evidence of Loss or Damage: 

This type of damage 

must

 be noted on 

the freight bill and acknowledged by the carrier’s agent (driver) at time of delivery. Make sure you get a signed 
copy. Send a written request for an inspection to the carrier.  

B.)

 

Concealed  Damage

:  This  type  of  damage  may  not  be  discovered  until  the  unit  is  being  unpacked.  When 

concealed  damage is discovered, stop unpacking immediately  and contact the carrier immediately to report 
the claim and request an inspection. This should be done as soon as possible and, in any case, must be done 
within 15 days or receiving the merchandise. If at all possible, do not  move the item and save  all packaging 
material for carrier’s inspection.  

C.)

 

FAILURE  TO  FOLLOW  THESE  INSTRUCTIONS  MAY  RESULT  IN  THE  CARRIER  REFUSING  TO  HONOR  YOUR 
COMPANY’S  CLAIM.  UNDER  NO  CIRCUMSTANCES  SHOULD  THE  MERCHANDISE  BE  RETURNED  TO  THE 
MANUFACTURER. NO RETURNS WILL BE ACCEPTED WITHOUT PRIOR AUTHORIZATION. 

 

 

 

Horizon Scientific 

125 Varnfield Drive 
Summerville, SC 29483 
Phone:  800-648-4041 
Fax:      843-821-8051 

Warranty: 

Two-Year Parts and Labor 
5 Years Compressor Parts 

Revision Date 

07/30/2013 

 

 

 

 

 

Содержание FS-RFC-30

Страница 1: ...on the freight bill and acknowledged by the carrier s agent driver at time of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This...

Страница 2: ...NTY 22 BEFORE CALLING THE MANUFACTURER S TECHNICAL SUPPORT DEPARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on...

Страница 3: ...Part number 20057 Rev 0 3...

Страница 4: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Страница 5: ...tion VOLTAGE SHOULD NOT VARY MORE THAN 5 FROM SERIAL PLATE RATINGS A separate circuit is recommended to prevent possible loss of product due to over loading or failure of other equipment on the same c...

Страница 6: ...rly Temperature control NOTE Temperature controls are preset at the factory to provide the desired air and product temperatures inside of the units and require no further adjustment Please contact us...

Страница 7: ...top shelf avoid blocking the evaporator fan s if installed There should be at least 4 inches of clearance below the fan s to allow proper air flow Do not overload the unit A full load is about 70 to...

Страница 8: ...at the unit is in a power lock up mode and that the unit must be reset To reset the unit and clear the message from the display remove the plastic panel located below the solar panels by using a blunt...

Страница 9: ...ssociated with the alarm system i e delay times system status a battery backup which will maintain the alarm system for several hours after a power failure to allow for continued alarm and notificatio...

Страница 10: ...ible tick to indicate a button has been pressed The MUTE PROGRAM button has three functions In Normal Run mode if the unit is beeping pressing the button will mute the beeper for a preset time Each ti...

Страница 11: ...rms When an alarm condition is declared the BEEPER and ALARM LED will both activate Press the MUTE PROGRAM button to stop the beeper for a specified time changing the sound to short chirps When the te...

Страница 12: ...n a short period 5 Once the Monitor is in Programming mode each time the Mute button is pressed the display steps to the next parameter As the display steps to the next parameter the value of the prev...

Страница 13: ...m condition still exists the beeper will begin to sound at full volume again This parameter can be set from 5 to 120 minutes To view the Highest temperature HOLD both the Hi and the Lo buttons togethe...

Страница 14: ...s remote alarms or central monitoring systems that an alarm condition has occurred at the unit being monitored The relay will pull in when line power is present If an alarm condition lasts for a desig...

Страница 15: ...n is marking on the chart paper If it is not then carefully adjust the pen arm to establish contact with the paper REPLACEMENT OF PEN Note In non inking units that is when using pressure sensitive rec...

Страница 16: ...the time to adjust the position of the first pen has expired the second pen will move onto the chart briefly stopping at the outer most temperature graduation of the chart at which time the second pe...

Страница 17: ...he arrow button must be held down until the green LED light goes out After the green LED light goes out follow the instructions in step 3 above Refer to the following figure for a diagram of the push...

Страница 18: ...placements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerat...

Страница 19: ...ent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURING THE...

Страница 20: ...o not wash removable shelves in dishwasher Exterior and Handles Soap and water Non Abrasive Glass Cleaner Do not use commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth...

Страница 21: ...ectly into a floor drain Replace the drain plug when defrosting is complete so warm air does not enter the freezer through the hole Defrosting tips If the frost is soft remove it with a plastic scrape...

Страница 22: ...Y In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship...

Страница 23: ...od or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage cause...

Отзывы: