ccessorIes
PLATFORMS
Platform can be used for mounting Erlenmeyer flask/media bottle clamps and test tube racks. Slides over-top included tray.
Tighten with adjustment screws. Stainless steel construction.
d
escrIPtIon
d
IMensIons
(l
x
W)
c
at
. n
o
.
Platform
33 x 28cm
444-7087
Platform
47,5 x 47,5cm
444-0697
33
x
28
cM
47,5
x
47,5
t
Ube
P
latforM
P
latforM
d
escrIPtIon
c
aPacIty
c
aPacIty
c
aPacIty
c
at
. n
o
.
Half Size Test Tube Racks
10 to 13mm Test Tube Rack
63
2
4
444-0278
14 to 16mm Test Tube Rack
48
2
4
444-0279
18 to 20mm Test Tube Rack
35
2
4
444-0280
22 to 25mm Test Tube Rack
24
2
4
444-0281
15mL Centrifuge Tube Rack
35
2
4
444-0283
50mL Centrifuge Tube Rack
12
2
4
444-0284
1,5 to 2mL Micro-Tube Rack
70
2
4
444-0276
Full Size Stationary Test Tube Racks
10 to 14mm Test Tube Rack
48
N/A
3
444-7037
16 to 20mm Test Tube Rack
33
N/A
3
444-7038
21 to 25mm Test Tube Rack
21
N/A
3
444-7039
Full Size Pivoting Test Tube Racks
13mm Test Tube Rack
90
N/A
2
444-2955
16mm Test Tube Rack
60
N/A
2
444-2956
20mm Test Tube Rack
40
N/A
2
444-2957
25mm Test Tube Rack
24
N/A
2
444-2958
30mm Test Tube Rack
21
N/A
2
444-2959
TEST TUBE RACKS - Requires Platform accessory.
Installation of Half Size Test Tube Racks:
1. Unit should be in standby mode.
2. Remove non-skid rubber mat. Slide Platform over-top included tray.
3. Using the hardware provided, attach brackets to the Platform. Position brackets as
shown. The proper spacing between the brackets is 19,7cm.
4. Align the test tube rack side-to-side with the brackets on the Platform.
5. Press the test tube rack in place, you will hear the test tube rack clip into position. No
mounting screws are required.
Installation of Full Size Pivoting Test Tube Racks (Model 5000I/5000IR Only):
1. Unit should be in standby mode.
2. Line up the 4 openings on the bottom of the outer rack with the four compatible
openings on the Universal Platform. Secure with the four screws provided.
3. If a tilt angle is desired, loosen wing knobs, tilt inner holder and tighten knobs.
4. To maximize the platforms capacity for holding racks in the stationary position, remove
the outer holder and secure the inner holder to the Universal Platform using the four
openings on the bottom of the inner holder.
Installation of Full Size Stationary Test Tube Racks (Model 5000I/5000IR Only):
1. Line up the two openings on the sides of the test tube rack with the two compatible
openings on the Universal Platform.
2. Place the washer on top of the opening on the test tube rack, place the clamp knob
through the washer and rack and hand tighten the clamp knob to the platform.