SAFETY RULES
Follow all operating rules presented in the introduction to the manual.
•
All operations with the radiator should be performed with the burner off, after radiator
cool off
•
Exchange of the cylinder and the vent of the gas system of the radiator should be performed
only in the open space, away from source of fire
•
During work, some part of the radiator get really hot, and in particular: the panes.
Touching these parts during the work and up to 10 minutes after switching the burner off can
cause burns or the ignition of the flammable materials in contact with these parts.
•
Each time after the exchange of the gas bottle you should check the tightness of the has hose
connection to the burner, reducer and cylinder. Before connecting visually check whether the
connection set is not damage. It is recommended to replace the hose with a new one at
least once a year.
•
The radiator during operation should be on the flat, stable surface providing adequate distance
from any materials with flammability characteristics or which can, under the influence of heat, get
damaged (deformation, sintering, melting). The minimum distance from each side of the radiator
from elements made of these materials should be at least 1,2 meters. When operating the
radiator under a roof, or in built-up areas, you should provide sufficient ventilation (at least 20%
of the open volume).
•
The radiator should be operated by adults, who are familiar with the operation manual.
The radiator should be protected from the reach of children and animals.
•
The radiator used in an open space should be secured against adverse weather conditions. You
should not use the radiator in strong wind and during rain or snow.
•
In direct contact of the heated panes with water there is a risk that the stresses will cause the
formation of cracks or splash of glass. In this case there is a danger of injury to persons in the
vicinity.
•
When operating under the open roof (umbrellas), when the burner is set in the position (3) LOW
their height should not be smaller than 2,5 m (during the operation you should control the
heating of the roof).
•
Do not use the radiator near the accumulated combustible materials.
•
In case of stating any damage to the radiator, and especially the malfunction of the burner,
breakage of the panes or feeling the characteristic smell of gas, you should immediately turn the
radiator off, twist and disconnect the gas cylinder.
•
In this case, you should wait until the radiator cools down and perform the corrective actions
specified in the section “Troubleshooting”, or contact with the manufacturer’s service.
7