VHLD SERIES
SUPER STEAMER, DIRECT STEAM
TWO OR THREE COMPARTMENT MODELS
SERVICE CONNECTIONS:
Steam Supply:
3
/
4
" NPT for 10 - 50 psi direct steam.
Electric Connection for Controls: 120/60/1, 300 watt maximum
power supply with grounding wire required. (For other than 120 volt
supply, consult factory for location of this conneciton.)
Drain: Condenser box, compartment and boiler, 2" NPT. (Provide
an open air gap type drain within 12" of condenser box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any
drain connection.)
EQUIPMENT CLEARANCE:
Rear: 6"
Right and left side: 6"
PAN CAPACITIES (Per compartment)
MODEL
2
1
/
2
" deep
4" deep
6" deep
18" x 26"
VHLD
8
6
4
6
NOTE:
• Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific
code requirements is the responsibility of the owner and installer. It is
the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.