F38237 (10/09)
A properly sized gas pressure regulator suitable for battery
1.
or single unit application must be furnished and installed.
Natural gas 6.0" W.C., propane gas 10 W.C.
An adequate ventilation system is required for commercial
2.
cooking equipment. Information may be obtained by
writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org.
When writing, refer to NFPA No. 96.
These units are manufactured for installation in
3.
accordance with ANSZ223.1A (latest edition), National
Fuel Gas Code. Copies may be obtained from The
American Gas Association, 400 N Capitol St. NW,
Washington, DC 20001, www.AGA.org.
Clearances
4.
Rear
Sides
Combustible
10"
10"
Non-combustible
0"
0"
For proper combustion, install equipment on adjustable
5.
legs or casters. On curb or platform, allow 3-
1
⁄
2
" front
overhand. Toe base with leveling bolts are required for
curb installation. Specify when ordering.
Cannot be batteried with GH series equipment.
6.
This appliance is manufactured for commercial
7.
installation only and is not intended for home use.
NOTE: In line with its policy to continually improve its
product, Vulcan reserves the right to change materials
and specifications without notice.
Specify type of gas when ordering. Specify altitude when
above 2,000 feet.
INSTALLATION INSTRUCTIONS
TOP
CONFIGURATION
MODEL
NUMBER
DESCRIPTION
TOTAL INPUT
BTU / HR
SHIPPING WEIGHT
LBS / KG
VGM36
36" Wide Manual Griddle / Modular
90,000
404 / 183
VGM36B
36" Wide Manual Griddle / Cabinet Base
90,000
504 / 229
VGM36S
36" Wide Manual Griddle / Standard Oven
140,000
685 / 311
VGM36C
36" Wide Manual Griddle / Convection Oven
122,000
763 / 346
Vulcan & Wolf Range
a division of ITW Food Equipment Group LLC
P.O. Box 696
n
Louisville, KY 40201
n
Toll-free: 1-800-814-2028
n
Local: 502-778-2791
n
Quote & Order Fax: 1-800-444-0602
HEAVY DUTY GAS RANGE
36" WIDE MANUAL GRIDDLE GAS RANGE
V
ULCAN
V S
ERIES
H
EAVY
D
UTY
R
ANGES