Vulcan-Hart VCE6H Скачать руководство пользователя страница 2

Printed On Recycled Paper

VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028

502-778-2791

QUOTE & ORDER FAX: 1-800-444-0602

NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.

F-32445 (10-03)

MODEL VCE6H

ELECTRIC COMBI OVEN

ACCESSORIES

Stainless steel stand with (legs)/(casters).

Pan slides for stand.

Mobile landing table.

Flexible water connection with (

3

/

4

" NSHT) - 2 required.

Spray down hose with retaining hook, 118" long with 

3

/

4

" NSHT.

Pan rack assembly.

Wire racks. Qty._____.

Chicken rack. Qty._____.

Stacking kit (legs)/(casters):

- Six half on six half.

- Six half on ten half (refer to VCE10H spec no. F32136).

- Six half on ten full (refer to VCE10F spec no. F32138).

Additional pan rack insert. Qty._____.

WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:

SUPPLY PRESSURE

20 - 60 psig

HARDNESS*

less than 3 grains

SILICA

less than 13 ppm

TOTAL CHLORIDE

less than 4.0 ppm

pH RANGE

7-8

UN-DISSOLVED SOLIDS

less than 5 microns

* 17.1 ppm = 1 grain of hardness

Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.

CLEARANCES:

4" right

6" rear

SERVICE CONNECTIONS:

E

Electric connection:

C1 Cold water connection:

3

/

4

" NSHT for generator feed. Inlet water

pressure between 20 and 60 psi.

C2 Cold water connection:

3

/

4

" NSHT for cold water condenser.

Inlet water pressure between 20 and 60 psi.

D

Drain: Condensate box, ompartment and boiler 1

1

/

2

" NPT. (Provide

an open air type drain within 12" of condensate box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any
drain connection.)

NOTE:

• Dimensions which locate the above connections have a tolerance of

+ or -3" (+ or -75 mm).

• Installation of backflow preventers, vacuum breakers and other spe-

cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.

• Plastic drains are not recommended due to inherent limited tempera-

tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140°F
or less.

• This appliance is manufactured for commercial installation only and is

not intended for home use.

PAN CAPACITY

STEAM TABLE PANS

BAKE PANS

12" x 20" x 2

1

/

2

"

12" x 20" x 4"

18" x 13"

18" x 26"

6

3

6

N/A

ELECTRICAL RATING

208V/60/3

240V/60/3

480V/60/3

KW

AMP

KW

AMP

KW

AMP

9

26

9

22

9

11

Отзывы: