Printed On Recycled Paper
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791
QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32445 (10-03)
MODEL VCE6H
ELECTRIC COMBI OVEN
ACCESSORIES
■
■
Stainless steel stand with (legs)/(casters).
■
■
Pan slides for stand.
■
■
Mobile landing table.
■
■
Flexible water connection with (
3
/
4
" NSHT) - 2 required.
■
■
Spray down hose with retaining hook, 118" long with
3
/
4
" NSHT.
■
■
Pan rack assembly.
■
■
Wire racks. Qty._____.
■
■
Chicken rack. Qty._____.
■
■
Stacking kit (legs)/(casters):
- Six half on six half.
- Six half on ten half (refer to VCE10H spec no. F32136).
- Six half on ten full (refer to VCE10F spec no. F32138).
■
■
Additional pan rack insert. Qty._____.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE
20 - 60 psig
HARDNESS*
less than 3 grains
SILICA
less than 13 ppm
TOTAL CHLORIDE
less than 4.0 ppm
pH RANGE
7-8
UN-DISSOLVED SOLIDS
less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.
CLEARANCES:
4" right
6" rear
SERVICE CONNECTIONS:
E
Electric connection:
C1 Cold water connection:
3
/
4
" NSHT for generator feed. Inlet water
pressure between 20 and 60 psi.
C2 Cold water connection:
3
/
4
" NSHT for cold water condenser.
Inlet water pressure between 20 and 60 psi.
D
Drain: Condensate box, ompartment and boiler 1
1
/
2
" NPT. (Provide
an open air type drain within 12" of condensate box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any
drain connection.)
NOTE:
• Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other spe-
cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140°F
or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.
PAN CAPACITY
STEAM TABLE PANS
BAKE PANS
12" x 20" x 2
1
/
2
"
12" x 20" x 4"
18" x 13"
18" x 26"
6
3
6
N/A
ELECTRICAL RATING
208V/60/3
240V/60/3
480V/60/3
KW
AMP
KW
AMP
KW
AMP
9
26
9
22
9
11