IMPORTANT

1. A properly sized gas pressure regulator suitable for battery or

single unit application must be furnished and installed.
Natural gas 5.0" W.C., propane gas 10.0" W.C.

2. An adequate ventilation system is required for commercial

cooking equipment. Information may be obtained by writing to
the National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269. When writing refer to NFPA No. 96.

3. These units are manufactured for installation in accordance

with ANSZ223.1a (latest edition), National Fuel Gas Code.
Copies may be obtained from the American Gas Association,
1515 Wilson Blvd., Arlington, VA 22209.

4. Clearances:

Combustible

Non-Combustible

Rear

2"

0"

Sides

20"

2"

5. For proper combustion, install equipment on adjustable legs

or casters. On curb or platform, allow 3

1

/

2

" front overhang.

Leveling bolts are required for curb installation. Specify when
ordering.

6. Cannot be batteried with GH series equipment.

7. This appliance is manufactured for commercial installation

only and is not intended for home use.

V-24S SERIES

24" WIDE HEAVY DUTY GAS RANGE WITH OPEN
CABINET BASE

WORKING

APPROX.

MODEL

BTU/HR.

HEIGHT

SHP. WT.

NO.

INPUT

WIDTH

DEPTH

ON 6" LEGS

(lbs./kg)

V4-24S

120,000

24"

38"

36"

295/133

V1G-24S

60,000

360/162