— 4 —

1. Bring conduit containing the proper supply wire to the fryer.

On VF1/VMF1 and VF1D/VMF1D, bring the conduit in through the clearance hole in the back and
terminate on the terminal block housing mounted in the back of the breaker box.

On VF2 and VF2D, terminate the field supply conduit on the corner of the bottom floor and bring
the supply leads into the breaker box through the removable channel mounted to the right side.

On VMF2 and VMF2D, bring the conduit through the opening in the bottom toward the front of the
fryer.

2. Connect the supply leads to the field terminal block and the green grounding lead to the labeled

ground lug.

Fryers wired for 3-phase service may be changed to 1-phase or vice versa by relocating two wires on
the terminal block as shown on the wiring diagram and the schematic decal which is attached to the
fryer.

ELECTRICAL DATA CHART

TOTAL    3-PHASE LOADING

NOMINAL AMPS PER LINE WIRE

MODEL

K.W.        KW PER PHASE

3 PHASE

1 PHASE

CONN.      208, 240 & 480 V.

208 V.

240 V.

480 V.

208 240 480

X-Y

Y-Z

X-Z

X

Y

Z

X

Y

Z

X

Y

Z

V.

V.

V.

VF1/VMF1,

12

3.8

3.8

4.2

34

33

34

29

28

29

15

14

15

58

50

25

VF1D/VMF1D
VF2/VMF2,

21.0

5.25

10.5

5.25

44

66

66

38

57

57

20

30

30

101

88

44

VF2D/VMF2D

LEVELING

Level floor model fryers.  Place a carpenter's level on top of the fryer and turn the adjustable legs to
level fryer front-to-back and side-to-side.

Countertop models must be placed on a level surface.

BEFORE FIRST USE

Clean fryer thoroughly, following procedures described in this manual under CLEANING — WEEKLY
OR AS REQUIRED.  Clean all fryer accessories.  Rinse all parts thoroughly and wipe dry.

Lightly season backsplash area to avoid possible surface corrosion.  With a soft, lint-free cloth, apply
a thin layer of cooking oil over entire backsplash area.  This should also be done after every cleaning.

Содержание ML-52532

Страница 1: ... FRYERS MODEL VF1 ML 52913 VMF1 ML 52914 VF2 ML 52915 VMF2 ML 52916 VF90 ML 52917 VFD90 ML 52532 VF1D ML 52538 VMF1D ML 52539 VF2D ML 52542 VMF2D ML 52543 VULCAN HART COMPANY P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 INSTALLATION OPERATION MANUAL VF1 ...

Страница 2: ...kets Stainless steel side s and back are also available optionally AUTOMATIC BASKET MELT MODEL WIDTH STYLE CONTROLS LIFT CYCLE VF1 20 Floor model Mechanical Opt Opt VMF1 20 Countertop Mechanical Opt Opt VF2 24 Floor model Mechanical Opt Opt VMF2 24 Countertop Mechanical Opt Opt VF1D 20 Floor model Solid State Opt Std VMF1D 20 Countertop Solid State Opt Std VF2D 24 Floor model Solid State Opt Std V...

Страница 3: ... for easy accessibility for service INSTALLATION CODES AND STANDARDS Vulcan fryers must be installed in accordance with In the United States 1 State and local codes 2 National Electrical Code ANSI NFPA No 70 latest edition Copies may be obtained from The National Fire Protection Association Batterymarch Park Quincy MA 02269 3 NFPA Standard 96 ELECTRICAL CONNECTIONS WARNING ELECTRICAL AND GROUNDING...

Страница 4: ...e schematic decal which is attached to the fryer ELECTRICAL DATA CHART TOTAL 3 PHASE LOADING NOMINAL AMPS PER LINE WIRE MODEL K W KW PER PHASE 3 PHASE 1 PHASE CONN 208 240 480 V 208 V 240 V 480 V 208 240 480 X Y Y Z X Z X Y Z X Y Z X Y Z V V V VF1 VMF1 12 3 8 3 8 4 2 34 33 34 29 28 29 15 14 15 58 50 25 VF1D VMF1D VF2 VMF2 21 0 5 25 10 5 5 25 44 66 66 38 57 57 20 30 30 101 88 44 VF2D VMF2D LEVELING...

Страница 5: ...ot shown Position on MELT when solid shortening is being melted then position on FRY for normal operation Automatic Basket Set to desired frying cycle time At end of set time baskets will automatically Lift Timers Optional raise Timer range is from 0 to 15 minutes Ball Pull Rod Models VF1 VMF1 only Raises elements from tank when pulled straight out Lowers elements into tank when pushed in VF1 VMF1...

Страница 6: ...t When ON indicates that the oil temperature is higher than 400 F or that the heating elements are not covered with shortening and the system has shut down Call your Vulcan Hart authorized servicer Temperature Controller Controls temperature of oil in tank Temperature range is 0 375 F Fry Melt Switch Position on MELT when solid shortening is being melted then position on FRY for normal operation B...

Страница 7: ...anty may be voided by improper operation Models VF1 VMF1 and VF1D VMF1D 1 Push power switch to OFF and allow fryer to cool 2 Remove fryer baskets 3 Leave the heating elements in the tank 4 Place 30 35 pounds of solid block shortening in the fryer tank on top of the heating elements 5 Follow melt cycle operation Models VF2 VMF2 and VF2D VMF2D 1 Remove fry basket and rack support 2 Place 78 82 pound...

Страница 8: ...ed remove baskets or product Hang baskets to drain on rear basket hangers Remove food and season it Do not salt food over the shortening because salt will cause a chemical change in the oil Add fresh shortening as needed Shortening should be between 1 and 2 inches above the heating elements TURNING THE FRYER OFF To turn the fryer OFF place the ON OFF switch to the OFF position Extended Shutdown Pl...

Страница 9: ...mpartment To start the syphoning action push the stopper in the bowl closed Fill the bowl with clean liquid shortening Pull the stopper to allow shortening to start draining Push the stopper closed before all the shortening is drained from the bowl To stop draining pull the stopper and empty the bowl completely Fig 5 Models VMF1 VMF1D Turn the fryer off and allow shortening to cool Place the sypho...

Страница 10: ...eaning is neglected grease will be burned on and discolorations may form These may be removed by washing with any detergent or soap and water A self soaping scouring pad may be used for particularly stubborn discolorations Always rub with the GRAIN in a horizontal direction Keeping the fryer exterior clean and free of accumulated grease will prevent stubborn stains from forming Wash all exterior s...

Страница 11: ... valve Models VF2 VMF2 and VF2D VMF2D only 10 Add shortening until the level is between 1 and 2 inches above the heating elements The fryer is now ready for use Heat Tint In and around equipment where temperatures reach 500 F or more straw colored or slightly darkened areas may appear on stainless steel This Heat tint is caused by a slight oxidation of the stainless steel and is not harmful To con...

Страница 12: ...TANK LUBRICATION The motors in all fryers are permanently lubricated and no lubrication is required SERVICE AND PARTS INFORMATION To obtain service and parts information concerning these fryers contact the Vulcan Hart Service Depot in your area refer to listing supplied with the fryer or Vulcan Hart Company Service Department at the address or phone number shown on the front cover of this manual F...

Отзывы: