— 9 —
F35641 (02-05)
EF SERIES GAS FRYERS
3. Remove thermopile from pilot bracket by
loosening the holding nut (Figure 13).
Figure 13
4. Reverse procedure to install.
PILOT ORIFICE
WARNING:
SHUT OFF THE GAS BEFORE
SERVICING.
WARNING:
ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED
FOR LEAKS. CHECK WITH SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
1. Remove the screw securing the Pilot/
Thermopile Assembly Bracket to the tank
front. Lower the assembly away from the
tank (Figure 12).
2. While holding assembly in the palm of
your hand remove the pilot compression
fitting at the bottom of the pilot to expose
the orifice (Figure 12).
3. Replace orifice and reverse procedure to
assemble.
PILOT
WARNING:
SHUT OFF THE GAS BEFORE
SERVICING.
WARNING:
ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED
FOR LEAKS. CHECK WITH SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
1. Remove the screw securing the Pilot/
Thermopile Assembly Bracket to the tank
front. Lower the assembly away from the
tank (Figure 12).
2. While holding assembly in the palm of
your hand remove the pilot compression
fitting at the bottom of the pilot and
disconnect the pilot tubing (Figure 12).
3. Remove thermopile as outlined under
Thermopile (set aside for reassembly).
4. Remove (2) screws holding the pilot
assembly to the Pilot/Thermopile
Assembly Bracket and replace the old
pilot with the new assembly (Figure14).
Figure 14
5. Reinstall by reversing steps 1-4.
Содержание ECONOFRY EF3 ML-52099
Страница 20: ...F35641 02 05 PRINTED IN U S A ...