GENERAL 

 
Heavy Duty Gas Griddles are produced with quality workmanship and materials. Proper 
installation, usage and maintenance of your griddle will result in many years of 
satisfactory performance. Thoroughly read this entire manual and carefully follow all of 
the instructions provided 
 

 

 

 

 

  

 

 

 

Model 

Number of Burners 

BTU/hr Input Rating 

924RE, AGE24 

60,000 

936RE, AGE36 

90,000 

948RE, AGE48 

120,000 

960RE, AGE60 

150,000 

972RE, AGE72 

180,000 

 

INSTALLATION 

Before installing, verify that the electrical service and type of gas supply (natural gas or 
propane) agree with the specifications on the rating plate riveted to the right side of the 
unit in the upper front corner. If the supply and equipment requirements do not agree, do 
not proceed with the installation. Contact your dealer immediately. 

 
UNPACKING 

This griddle was inspected before leaving the factory. The transportation company 
assumes full responsibility for safe delivery upon acceptance of shipment. Check for 
possible shipping damage immediately after unpacking. If the griddle is found to be 
damaged, save the packaging material and contact the carrier within 15 days of delivery. 
 
Carefully unpack your griddle and make sure that no parts are discarded with packaging 
material. A pressure regulator designed to operate with the griddle has been supplied and 
must be installed before the griddle is placed into service (Refer to GAS PRESSURE 
REGULATOR INSTALLATION in this manual).  
 

LOCATION 

The installation location must be kept free and clear of combustibles. When installing, 
never enclose the bottom of the griddle with a raised curb or other constructions that 
would obstruct flow of air into or out of the griddle. Adequate clearance for air openings 
into the combustion chamber must be provided. Make sure there is an adequate supply of 
air in the room to replace air taken out by the ventilation system. 

Do not permit air to blow directly at the griddle. Avoid open windows next to the griddle 
wherever possible. Avoid wall-type fans which create air cross-currents within the room. 

Содержание 948RE

Страница 1: ...OPERATION MANUAL FOR Heavy Duty Gas Griddles MODEL MLS 924RE ML 135221 00G24 936RE ML 135222 00G36 948RE ML 135223 00G48 960RE ML 135224 00G60 972RE ML 135225 00G72 www vulcanhart com 924RE AGE24 MODE...

Страница 2: ...ORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLA...

Страница 3: ...s full responsibility for safe delivery upon acceptance of shipment Check for possible shipping damage immediately after unpacking If the griddle is found to be damaged save the packaging material and...

Страница 4: ...est edition available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2...

Страница 5: ...ddle and its individual shutoff valve must be disconnected from the gas supply piping system When the gas supply pressure is psig 3 45 kPa or less the griddle should be isolated from the gas supply sy...

Страница 6: ...ventilated to the outside of the building through a ventilation system installed by qualified personnel From the termination of the flue to the filters of the hood venting system a minimum clearance...

Страница 7: ...le OFF then measure the temperature for that zone The temperature should be 350 F 15 F If not continue to Step 4 Step 4a Set knob check Temperature Remove knob Step 4b Adjust temperature dial verify t...

Страница 8: ...dure until the griddle has a slick mirror like finish CONTROLS THERMOSTAT Each thermostat controls the gas flow to the burner to bring that area of the griddle plate up to the set temperature Indicato...

Страница 9: ...ostats Each 12 section is a separate cooking zone and allows cooking a wide variety of products over a single griddle plate The chart below is a suggested usage of zone cooking When zone cooking it is...

Страница 10: ...ry cooking utensil ONCE PER WEEK Clean the griddle surface thoroughly Use a griddle stone screen or Scotch Bright pad on the surface as necessary Rub with the grain of the metal while the griddle is s...

Страница 11: ...com When calling for service the following information should be available from the appliance serial plate Model Number Serial Number Gas Type and Voltage ACCESSORIES STANDS The griddle has an option...

Страница 12: ...will not stay lit 1 Low gas pressure problem with regulator or system gas pressure Verify or Call for Service 2 Obstructed or wrong size pilot orifice Call for service 3 Gas supply not purged of air C...