8
CAUTION
!
l
All air line components (including hoses, pipe, connectors, filters, & regulators, etc.) must
be rated for a minimum working pressure of 150 psi or 150% of the maximum system
pressure, whichever is greater.
l
Disconnect the tool from the air supply before loading fasteners, performing maintenance,
clearing a jammed fastener, leaving the work area, moving the tool to another location, or
handing it to another person.
LOADING THE FASTENERS
CAUTION
!
l
Keep the tool pointed away from yourself and others at all times.
l
Do not load fasteners with safety or trigger depressed.
l
Always wear approved safety glasses and hearing protection when preparing or operating
this tool.
l
Never use a tool that leaks air or needs repair.
1. Disconnect the tool from the air supply before loading fasteners.
2. Depress the Lock (59) to release the
MOVABLE MAGAZINE (57) and pull the
magazine out fully as shown.
3. Being certain the gun is aimed in a safe
direction, place a full stick of the desired
type and size of fasteners on the FIXED
MAGAZINE (53). Staples should be
placed to straddle the central spine of the
FIXED MAGAZINE UNIT, and brad nails
are laid up against its left side, placed
points-down in the slot at the bottom
of the FIXED MAGAZINE. Up to 100
fasteners can be loaded in the magazine.
4. Push the MOVABLE MAGAZINE UNIT
(57) forward until the LOCK (59) clicks and secures it in place.
5. The tool is ready to operate.
CONNECTING THE TOOL
1. Be sure the tool’s lubrication needs are met.
2. Load fasteners.
3. Turn the compressor on.
4. Set the regulator to proper pressure for the size and type of fasteners being used.
5. After reading and understanding this entire manual, connect tool to air supply.
Содержание 404-7791
Страница 14: ...14 SCHEMATIC DRAWING...